    Travis SinghAug 17, 2025
    Why is the DeZurik Control Unit valve leaking when closed?
    • R
      Richard BullockAug 17, 2025
      The DeZurik Control Unit valve might leak when closed due to several reasons: * The closed position stop may be set incorrectly, requiring adjustment. * The seat could be worn or damaged, necessitating replacement. * The sealing edge of the disc might be worn or damaged, also requiring replacement.
  • K
    Kevin BruceAug 19, 2025
    What to do if my DeZurik BHP valve does not fully close?
    • B
      Brian MccormickAug 19, 2025
      If your DeZurik Control Unit valve does not fully close, consider the following: * An object might be wedged between the disc and seat. Try opening the valve to allow flushing action to remove the object. * The closed position stop may not be adjusted correctly. Adjust the closed stop. * The disc-to-shaft connection might have failed. Replace the disc pins and/or shaft.
  • T
    Theresa BaxterAug 22, 2025
    What to do if my DeZurik BHP Control Unit valve does not fully open?
    • M
      Mark RodriguezAug 22, 2025
      If the DeZurik Control Unit valve does not fully open, it could be due to: * Incorrect adjustment of the open position stop. Adjust the open stop. * Failure of the disc-to-shaft connection. Replace the disc pins and/or shaft.
  • M
    mcdanielchristopherAug 25, 2025
    Why is the opening or closing torque excessive on my DeZurik Control Unit?
    • H
      hardintimothyAug 25, 2025
      Excessive opening or closing torque on your DeZurik Control Unit can occur if: * Bearings, shaft, disc, and/or seat are dirty or worn. Clean or replace the dirty or worn components. * The shaft is bent. Replace the shaft.
  • S
    Suzanne NicholsonAug 27, 2025
    What to do if DeZurik BHP Control Unit valve components are corroding?
    • M
      Madison BrownAug 27, 2025
      If the DeZurik Control Unit valve components are corroding, it is likely because the media is corrosive and incompatible with the valve material. Replace the existing valve with a valve constructed of material compatible with the media.
  • P
    pgrossAug 30, 2025
    Why is my DeZurik BHP Control Unit valve body leaking from the seat retainer area?
    • P
      Phillip ThomasAug 30, 2025
      If your DeZurik Control Unit valve body is leaking from the seat retainer area, the cause may be: * Loose pipeline flange bolting. Tighten the pipeline flange bolts. * Misaligned pipeline flanges. Align the pipeline flanges. * A worn pipeline flange gasket or seat retainer gasket. Replace the gasket(s).
  • O
    Olivia PaulSep 2, 2025
    How to fix packing leaks in DeZurik BHP?
    • R
      Robert KingSep 2, 2025
      Packing leaks in the DeZurik Control Unit can be fixed by: * Adjusting the packing if it is loose. * Replacing the packing if it is worn.
  • B
    Brandon ThomasSep 5, 2025
    What to do if seat leakage and/or damage to seat has occurred in DeZurik Control Unit due to abrasive media?
    • C
      Christine ParksSep 5, 2025
      If seat leakage and/or damage to the seat has occurred in your DeZurik Control Unit because the media is abrasive, replace the existing seat with a seat that is suitable for abrasive media.
  • K
    kennethcherrySep 7, 2025
    What to do if DeZurik Control Unit valve leakage and/or damage to valve has occurred?
    • D
      denisehullSep 7, 2025
      If valve leakage and/or damage to the valve has occurred in your DeZurik Control Unit, it may be because the valve encountered higher than rated pressure. Reduce the media pressure.
  • R
    Robert HarrisSep 10, 2025
    What to do if DeZurik BHP valve components are eroding?
    • P
      Patrick HarrisSep 12, 2025
      To address eroding valve components in your DeZurik Control Unit, replace the valve with materials suitable for abrasive media.

Summary

Valve Safety Messages

Valve Installation Guide

Valve Operation and Packing Adjustment

Replacing Valve Packing Procedures

PTFE V-Flex Dual-Seal Live-Loaded Packing Option (TCDL)

Procedure for replacing PTFE V-Flex Dual-Seal Live-Loaded packing.

PTFE V-Flex Packing Option (TC)

Procedure for replacing PTFE V-Flex packing.

PTFE Dual-Seal with Mechanical Spring Packing Option (TMD)

Procedure for replacing PTFE Dual-Seal with Mechanical Spring packing.

Torque Specifications

Valve Seat Replacement

Resilient Seat Options

Metal Seat Option

Dual Seat Options

Valve Disassembly Guide

Valve Bearing Replacement

Valve Reassembly Guide

Troubleshooting Valve Issues

DeZurik BHP Specifications

General IconGeneral
BrandDeZurik
ModelBHP
CategoryControl Unit
LanguageEnglish