www.diamaticusa.com
info@diamaticusa.com
The choice of professionals
US
6/12
Technical specications
Parameter Units 3140 DBP/LPP
Voltage / frequency V/Hz 230/60 440/60**
230/60
440/60**
Power rating*** kW 6,85 6,85 5,15
Noise level dB(A) 80 80 72
Peak noise* dB(A) 81 81 75
Protection IP 55 55 55
Insulation Class F F f
Container capacity L 100 100 100
Inlet (diameter) mm 70 70 70
Max vacuum hPa - mbar 206 - 206 206 - 206 226-226
Maximum air ow rate (with hose, length: 3 m, diameter: 76 mm) m
3
/h - L/min’ 550 - 9250 550 - 9250 462-7700
Main lter surface m
2
15 15 15
Upstream absolute “H” lter surface - HEPA 14 according to
MPPS method (EN 1822)
m
2
3,5 3,5 3,5
* When the compressor is operating
** 400-480V/60 Hz
*** Suction unit + compressor
Parameter Units 3140 DBP/LPP
Voltage / frequency V/Hz 230/60 440/60**
230/60
440/60**
Power rating*** kW 6,85 6,85 5,15
Noise level @ 3’3” (1 meter) dB(A) 80 80 72
Peak noise* dB(A) 81 81 75
Protection IP 55 55 55
Motor insulation Class F F F
Container capacity Gallons/litres 26 - 100 26 - 100 26-100
Inlet (diameter) Inches 3 3 3
Max vacuum Inches H
2
O 8.21 8.21 9.06
Max air ow rate cfm 327 327 272
Main lter surface Sq. ft 162 162 162
Absolute lter surface (HEPA optional) Sq. ft 38 38 38
Cable length ft 30 30 30
HEPA lter efciency MPPS tested
99.995% @
0.18 micron
99.995% @
0.18 micron
99.995% @
0.18 micron
* When the compressor is operating
** 400-480V/60 Hz