EasyManua.ls Logo

Dickinson P9000 - User Manual

Dickinson P9000
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Direct Draft Propane Heater
Operating + Installation
Instruction Manual
*
This instruction manual contains important information
necessary for the proper assembly and safe use of the appliance
*
P9000 & P12000 Model Heaters
**Read and follow all warnings and instructions before assembling and using
the appliance. Keep this manual for future reference**
Heater’s Serial #: __________________
Form#7.2-247 Issue#1 Nov 24, 2015

Questions and Answers

  • C
    colleenvaughnAug 9, 2025
    Why does my Dickinson P9000 Gas Heater smell like gas when off?
    • A
      Alisha JonesAug 9, 2025
      If you smell gas when the control knob is in the OFF position, it could be due to a gas leak. Locate and correct all leaks. Also, check and replace the control valve if needed, especially if high-pressure gas was used, as this can cause the valve to fail.
  • M
    Melissa BakerAug 13, 2025
    What to do if Dickinson P9000 shuts off during use?
    • G
      gdillonAug 14, 2025
      If your Dickinson Gas Heater shuts off during use, it could be due to a lack of gas supply. Check the gas pressure. Another possible reason is a blockage of the air intake. Inspect the vent pipe for any obstructions, including water.
  • M
    Michael CrawfordAug 19, 2025
    How to fix a Dickinson Gas Heater fan that doesn't work?
    • J
      Joseph LiuAug 19, 2025
      If the fan in your Dickinson Gas Heater is not working, first verify the power supply (12V DC). Then, check the wire connections and ensure the switch is functioning correctly. If none of these steps resolve the issue, the fan may need to be replaced.
  • R
    Renee SuarezAug 25, 2025
    What to do if Dickinson Gas Heater fire does not stay lit?
    • M
      Matthew CoxAug 25, 2025
      If the fire in your Dickinson Gas Heater does not stay lit when you release the knob: - Depress the knob, light the burner, and almost close the door. Release the knob and then CLOSE the combustion chamber door. - Check that the door seal is in good condition. - Confirm that the internal exhaust pipe is correctly installed.
  • J
    Jamie JohnsonAug 29, 2025
    How to troubleshoot Dickinson Gas Heater with no gas to burner?
    • R
      Robert FoxAug 29, 2025
      If there's no gas going to the burner when lighting your Dickinson Gas Heater: - Check the gas supply, regulator, and solenoid. - Make sure the knob is exactly on LOW (9 o'clock position) when pressed in. - Inspect the orifice for clogs due to dirt buildup or material from new hose installation.
  • P
    pramosSep 3, 2025
    Why does my new Dickinson P9000 Gas Heater smoke during initial operation?
    • D
      Diana DavisSep 3, 2025
      A slight smoke or odor during the initial operation of your Dickinson Gas Heater is normal. It is caused by the burning off of residues from the manufacturing process. The smoke and odor should stop after a few hours of operation.

Dickinson P9000 Specifications

General IconGeneral
Burner MaterialStainless Steel
CategoryGas Heater
Heat Output9000 BTU
Fuel TypePropane
Ignition TypePiezo Ignition