Thetablebelowshowstherelationbetweenpowerinterruptandappliancetime
independenceoftheparameter“HeaterProt”:
ValueHeaterProtOn-Time[ms]Off-Time[ms]Powerfactor
1
2
3
4
5
6
7
8
9
10
400
600
800
1000
1350
2000
2000
2000
2000
2000
100
100
110
120
150
200
180
150
100
80
0.80
0.86
0.88
0.89
0.90
0.91
0.92
0.93
0.95
0.96
3.PowerBoostMode
ThePowerBoostModeenablesaninitialshorttermhighpowerpulseappliedtothecoil(boost).Whenin
BoostMode,thepowersettingofboostappearsinthemainmenuaswellasintheExtendedFunctions/
Heatermenuunder“BoPwr”.
Besides12selectableinitialboosttimes,theDaniBoxMicrohasanewfeaturecalleddynamicboost:
When“dyn”isselectedfortheboosttime(”BoTim”intheExtendedFunctions/Heatermenu)theselected
boostpowerisappliedtothecoil,whenthefire-andplus-buttonarepressedsimultaneously.
MainMenu
ExtendedFunctions
HeaterMenu
05MainMenu(Page6)
(onlywhenExpertMode=1)
2.HeaterProtectionMode(onlywhenExpertMode=1)
Theheaterprotectionmodeisaperiodicinterruptionofthepowerappliedto
thecoil.Thedurationandtherepetitionrateoftheinterruptsisselectedby
meansoftheparameter“HtrProt”intheextendedfunctionsmod-menu.
Therepeatedpowerinterrupthelpstoavoidabreakinliquidflowandthus
anincreaseintemperature.
ExtendedFunctions
HeaterMenu
Parameter
Parameter
MainMenu
Thedynamicboostoperationisillustratedonthetopofthenextpage:Wheneverthefirebuttonandthe
plusbuttonarepressedatthesametime,theboostpowerisselectedandappliedtothecoil.Otherwise
justtheselectedpowerisapplied.
Notethatthemaximumdynamicboosttimeislimitedto2seconds!When2secondselapse,onlythepower
isappliedtothecoilregardlessoftheplusbutton.Allpowerlimtationsareactive,alsoduringtheboosttime.