INSTRUCTIONS: EKOS M1 230
TECHNICAL SPECIFICATIONS
Voltage
Power
Accessory power output
Automatic closing time
Operating time
Slowing time
Courtesy light time
Number of codes
Transmitters
Frequency
Operating temperature
Sensibility
Homologation
220 VAC +/- 10%
550 W
24 VAC 250mA
5 to 120 sec
3 to 120 sec
2 to 120 sec
2 to 180 sec
254 codes
Fix\Rolling code
433.92 / 868 Mhz
0 to 70°C
100dBm
Conf ETS 300-220/ETS 300
-683
Terminals Type Description
1 - 2com
NO START contact (Alternate Pulse OPEN/STOP/CLOSE/STOP)
3 - 2com
NO PEDESTRIAN contact
4 - 6com
NC BAND/PHOTOCELL OPENING contact (If you do not use it, please close the contact)
5 - 6com
NC PHOTOCELL CLOSING contact (If you do not use it, please close the contact)
7 - 6com
NC STOP contact (If you do not use it, please close the contact)
9 - 8com
NC LIMIT SWITCH OPENING contact
10 - 8com
NC LIMIT SWITCH CLOSING contact
11 - 12
24V ~ Photocells + accessories 24VAC 250mA power
13-14-15
220V ~
MOTOR input (13-14 electrical phases with a capacitor in parallel) (15 neutral/common)
16 - 18
220V ~ FLASHING LIGHT input
17 - 18
220V ~ COURTESY LIGHT input
19 - 20
220V ~ LINE input 220VAC
21 - 22
ANTENNA input (21 joiner / 22 signal)
L1 STATUS Led
On when the control panel is powered
L2 RADIO Led
On when you log in the radio memory
L3 PROGRAMMING TIME
Led
The led flashes during the programming
L4 START Led
On when you give a pulse
L5 PEDESTRIAN Led
On when you give a pedestrian pulse
L6 PHOTOCELL Led
On when the potocells are aligned
L7 L. S. OPENING Led
On when the limit switch is in N.C.
L8 L. S. CLOSING Led
On when the limit switch is in N.C.
L7+L8 STOP Led
Both on when the stop is in N.C.
LED READING
JUMPER J1
Radio memory opening by transmitter.(Possibility of storing from the ou-
tside the transmitters without operating on the control panel).
Insert jumper: ON OFF
TRIMMER T1
The Power Trimmer regulates the pair and the sensitivity in normal operation.
TRIMMER T2
The Power Slow Trimmer regulates the pair and the sensitivity in slowing.
- + The pair increases turning the trimmer in clockwise.
BUTTON P1
RADIO PROG button for the storage of the transmitters
BUTTON P2
TIME PROG button for the storage of the operating time
P1
P2
J1
T1 T2
L4 L5 L6 L7 L8
L2
L3
COM
N.C.
N.C.
N.C.
N.O.
N.O.
1234
5678
L1
N.C.
COM
N.C.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
COM
21 22
SELECTION
OPTIONS 1-8
P2
v M 01022012
Question and Answer IconNeed help?

Do you have a question about the Dieffematic EKOS M1 230 and is the answer not in the manual?

Summary

Technical Specifications

Configuration Controls

JUMPER J1

Configures radio memory opening by transmitter without control panel operation.

TRIMMER T1

Regulates pair and sensitivity in normal operation.

TRIMMER T2

Regulates pair and sensitivity during slowing.

BUTTON P1

RADIO PROG button for storing transmitters.

BUTTON P2

TIME PROG button for storing operating time.

LED Indicators

L1 STATUS Led

Indicates when the control panel is powered.

L2 RADIO Led

Indicates when a transmitter is logged into the radio memory.

L3 PROGRAMMING TIME Led

Flashes during the programming of operating time.

L4 START Led

Indicates when a pulse is given to start operation.

L5 PEDESTRIAN Led

Indicates when a pedestrian pulse is given.

L6 PHOTOCELL Led

Indicates when photocells are aligned.

L7 L. S. OPENING Led

Indicates when the opening limit switch is active.

L8 L. S. CLOSING Led

Indicates when the closing limit switch is active.

L7+L8 STOP Led

Indicates when the stop contact is active.

Encoder Operation

Change of Sensitivity According to the Pair

Adjusts sensitivity based on motor pair settings using T1 and T2 trimmers.

Dip-Switch Options Selection

Option 1: Garage; Sliding Section

Selects between garage operation or sliding gate operation mode.

Option 2: Automatic Closing

Enables or disables automatic closing after opening.

Option 3: Residential Mode; Step by Step

Configures operation mode for residential or step-by-step control.

Option 4: Inversion of Direction

Reverses motor movement direction relative to limit switches.

Option 5: Setup of Safety Contact in Opening

Defines safety contact behavior during the opening phase.

Option 6: Flashing Light Function

Controls the flashing light behavior (intermittent or fixed).

Option 7: Slowing

Enables or disables slowing function during gate movement.

Option 8: Encoder

Activates or deactivates the encoder input for position sensing.

Programming Functions

Transmitter Programming

Procedure for storing fixed and rolling code transmitters.

Pedestrian Passage Programming

Sets the pedestrian passage time (8 seconds) via transmitter.

Stored Codes Deleting

Procedure for erasing all stored transmitter codes.

Opening Time Programming

Sets the automatic opening and closing times for the gate.

Programming with Slowing

Guides programming of opening and closing times with slowing.

Programming Without Slowing

Guides programming of opening and closing times without slowing.

Dieffematic EKOS M1 230 Specifications

General IconGeneral
BrandDieffematic
ModelEKOS M1 230
CategoryControl Unit
LanguageEnglish

Related product manuals