XBeeāPRO®900HP/XBeeāPRO®XSCī ±RFī ±Modules
©2014DigiInternationalInc. 53
D1
DIO1 / AD1 Configuration (Pin 19). 
0 = Disabledļ 
1 = SPI Attention
2 = ADC
3 = Digital input
4 = Digital output low 
5 = Digital output high ļ 
6 = Uart Data Present Indicator
0-6 0
D2
DIO2 / AD2 Configuration (Pin 18). 
0 = Disabledļ 
1 = SPI Clock
2 = ADC 
3 = Digital input
4 = Digital output low 
5 = Digital output high 
0-5 0
D3
DIO3 / AD3 Configuration (Pin 17). 
0 = Disabledļ 
1 = SPI Slave Select
2 = ADC
3 = Digital input
4 = Digital output low 
5 = Digital output high 
0-5 0
D4
DIO4 Configuration (Pin 11). 
0 = Disabledļ 
1 = SPI_MOSI
3 = Digital input
4 = Digital output low 
5 = Digital output high 
 0, 1, 3-5  0
D5
DIO5 / ASSOCIATE_INDICATOR Configuration (Pin 15). 
0 = Disabled
1 = Associated Indicator
3 = Digital input
4 = Digital output low 
5 = Digital output high 
0, 1, 3-5  1
D6
DIO6 / RTS
 Configuration (Pin 16). 
0 = Disabled
1 = RTS flow control 
3 = Digital input
4 = Digital output low 
5 = Digital output high 
0, 1, 3-5 0
D7
DIO7 / CTS
 Configuration (Pin 12). 
0 = Disabled
1 = CTS flow control 
3 = Digital input
4 = Digital output low 
5 = Digital output high 
6 = RS-485 Tx enable, low TX (0V on transmit, high when idle) 
7 = RS-485 Tx enable, high TX (high on transmit, 0V when idle)
0, 1, 3-7  1
D8
DIO8 / SLEEP_REQUEST Configuration (Pin 9). 
0 = Disabled
1 = Sleep request
3 = Digital input
4 = Digital output low 
5 = Digital output high
0, 1, 3-5 1
D9
DIO9 / ON/SLEEP
 Configuration. (Pin 13) 
0 = Disabled
1 = ON/SLEEP
 output
3 = Digital input
4 = Digital output low 
5 = Digital output high
0, 1, 3-5 1
Tableī ±5ā09. I/Oī ±Settingsī ±andī ±Commands
ATļ 
Command
Name and Description Parameter Range Default