DigitAx User Guide
Issue code: dgxu4
11-12
Bit parameters (R–W)
Parameter Default Effect Name
b0b0 0 Disable Enable change of security code
b1b1 0 Not Recall parameter settings from EEPROM
b2b2 1 Enable Drive enable
b3b3 0 Not Alarm reset
b5b5 0 Not Recall default values from EEPROM
b6b6 0 Speed Reference selector
b7b7 0 Disable Enable ramps
b8b8 0 Analog Current reference mode selector
b11b11 0 Delimit Current limit selector
b12b12 0 (b13b13) Current signal selector
b13b13 0 TPRC Current signal source selector
b14b14 1 Analog ref. Reference selector
b15b15 0 Polarity Sign signal polarity selector
b16b16 0 Speed selector Digital input selector
b17b17 0 Analog Speed reference input selector
b18b18 0 Digital Digital stop selector
b21b21 1 Enable BCC enable
b22b22 1 Enable Normal-stop ramp function
b23b23 1 With Limit-switch ramp function
b49b49 0 Inactive Resolver phasing
b50b50 0 Return Display return function
b51b51 0 8-bit Serial link (interface) data format (parity)
b52b52 0 ANSI Serial link (interface) mode
b53b53 0 Stop and hold Digital stop mode selector
b56b56 0 Disable External trip (Et) enable
b88b88 0 +24V = STOP Invert logic of STOP signal
b96b96 1 Relative At-speed relative or absolute
b99b99 0 Not Save Working Table to EEPROM