FXL(N) FAN STORAGE HEATER RANGE
MODELS: FXL18N - 2.6kW / 18kWh STORAGE & 1.5kW BOOST
FXL24N - 3.4kW / 24kWh STORAGE & 1.5kW BOOST
INSTALLATION AND OPERATING
INSTRUCTIONS
IMPORTANT
PLEASE READ THIS LEAFLET CAREFULLY AND
RETAIN FOR FURTHER USE. NOTE ALSO THE
INFORMATION GIVEN ON THE HEATER
Ê The Installation must be carried out by trained personnel.
Ê A means for disconnection must be incorporated in the fixed wiring by a double pole switch with a
contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations.
Ê The heater must not be installed immediately below a fixed socket outlet.
Ê The heater is not suitable for connection to a 30A ring circuit.
Ê Do not position the heater under windows where curtains can contact the heater casing.
Ê WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
Ê This heater meets EN60335 safety requirements. However, any heater type becomes hot in normal
operation. Care must be taken to ensure that prolonged skin contact with the heater does not occur.
Ê WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE
MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
Ê This appliance is very heavy and must be securely fixed to a wall. DO NOT UNDER ANY
CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING
EXPERT ADVICE.
Ê To maintain stability, it is essential that the heater is placed on a level surface.
Ê This heater must be installed where it is impossible for switches and other controls to be touched by a
person using a bath or shower.
Ê IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the first few
days of operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS,
OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY
TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
Ê IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION
SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED
BY AN IDENTICAL PART.
Question and Answer IconNeed help?

Do you have a question about the Dimplex FXL18N and is the answer not in the manual?

Summary

Dimplex Heater Installation and Operation Overview

Important Safety and Commissioning Notes

Key warnings for installation, hot surfaces, young children, and initial operation smell.

Dimplex Heater Installation Steps

Preparation, Fixings, and Electrical Connections

Guidance on storage bricks, wall fixings, cable preparation, and wiring circuits.

Initial Assembly and Panel Removal

Steps for removing front panels, inner guards, and preparing the heater for brick loading.

Dimplex Heater Installation Details

Heater Placement and Wall Mounting

Instructions for fan speed selection, heater positioning, and wall bracket fixing.

Brick Loading and Final Assembly

Steps for loading storage bricks, refitting elements, guards, and securing the heater casing.

Dimplex Heater Operating Instructions

Principles of Operation

Explanation of heat retention, input control, core discharge, and boost heating.

Safety and Commissioning Procedures

Essential safety guidelines and procedures for the initial 48-hour commissioning period.

Control Functions and Settings

Details on setting room temperature, input controls, and boost option operation.

Cleaning, Maintenance, and Support

Guidance on cleaning, wall discolouration, and obtaining after-sales service.

Summary

Dimplex Heater Installation and Operation Overview

Important Safety and Commissioning Notes

Key warnings for installation, hot surfaces, young children, and initial operation smell.

Dimplex Heater Installation Steps

Preparation, Fixings, and Electrical Connections

Guidance on storage bricks, wall fixings, cable preparation, and wiring circuits.

Initial Assembly and Panel Removal

Steps for removing front panels, inner guards, and preparing the heater for brick loading.

Dimplex Heater Installation Details

Heater Placement and Wall Mounting

Instructions for fan speed selection, heater positioning, and wall bracket fixing.

Brick Loading and Final Assembly

Steps for loading storage bricks, refitting elements, guards, and securing the heater casing.

Dimplex Heater Operating Instructions

Principles of Operation

Explanation of heat retention, input control, core discharge, and boost heating.

Safety and Commissioning Procedures

Essential safety guidelines and procedures for the initial 48-hour commissioning period.

Control Functions and Settings

Details on setting room temperature, input controls, and boost option operation.

Cleaning, Maintenance, and Support

Guidance on cleaning, wall discolouration, and obtaining after-sales service.