Preconfiguring the Heat Pump Heating System 5.1
5 Preconfiguring the Heat Pump Heating System
The preconfiguration informs the controller about which
components are connected to the heat pump heating system.
Preconfiguration must be carried out before the system-specific
settings in order to show or hide menu items (dynamic menus).
The following table shows not only the menu structure and
explanations in the right-hand column, but also the
corresponding setting ranges. Values in bold print indicate the
factory settings.
The factory settings in the “Preconfiguration” menu correspond
to the integration diagram for a mono energy heat pump
(normally an air-to-water heat pump) with 1 compressor and a
heating circuit without DHW heating using the heat pump.
5.1 Menu
You can access the preconfiguration menu by:
Simultaneously pressing (approx. 5 seconds) the button
combination (ESC) and (MENUE).
Exit the preconfiguration via the button (ESC).
Abbreviations:
The following presettings must be carried out:
HP Heat pump
AW HP Air-to-water heat pump
BW HP Brine-to-water heat pump
WW HP Water-to-water heat pump

Preconfiguration of all system components for
dynamic menu structuring
Setting range Display
 
Monovalent (heat pump as sole heat
generator), mono energy (heat pump and
immersion heater), bivalent-parallel (heat
pump and boiler), bivalent-alternative (heat
pump or boiler), bivalent-regenerative (heat
pump or reg. heat source)
Monovalent
Mono energy
Bivalent-parallel
Bivalent-alternat.
Bivalent-regener.
Bivalent-regenerative,
with nonreversible HP
only
 

  
Has an additional heat exchanger with
supplementary connections for DHW
preparation been installed in the heat pump?
Yes
No
Reversible HP
AW HP
  
Has the system got an unmixed heating circuit? Yes
No
At all times
  
Has the system got a heating circuit 2 with a
controllable mixer?
No
Yes
At all times
  
Has the system got a heating circuit 3 with a
controllable mixer?
No
Yes
Heating circuit 2
Nonreversible HP
Nonbivalent system
 

Will the cooling function of the reversible heat
pump be used?
Yes
No
Reversible HP
 

Is a passive cooling controller connected to the
heating controller?
No
Yes
BW or WW HP
Nonreversible HP
  
 
Is a 2 or a 4-pipe system used for passive
cooling?
2-pipe system
4-pipe system
BW or WW HP
Nonreversible HP
Passive cooling function
 
Is DHW heating carried out by the heat pump? No
Yes
At all times