EN-16
9.1
English
 
The heat pump is blocked. The cause for the block is displayed using the following abbreviations:
ET: The external temperature is lower than -25 °C (or -15 °C) or higher than 35 °C.
OM: When the "Bivalent-alternative" operating mode is selected, the external temperature is
lower than the limit temperature HG2. The 2nd heat generator is released.
BR: When the "Bivalent-regenerative" operating mode is selected, the temperature in the
cylinder is high enough so that all pending requests (heating, hot water or swimming pool) can
be processed by the cylinder.
BF: The current return flow temperature is lower than the set limit.
DHW: Domestic hot water reheating via the 2nd heat generator is active.
SK: A system control was activated in the special functions menu. It will be automatically
deactivated after 24 hours.
EVS: Utility block (EVU) or bridge A1 (ID3-X2) has not been inserted.
Def: With measure defrost active the usual lowering of the flow temperature during defrosting
did not occur.
PR: The current pressure value in the refrigerant circuit is above the permitted limit.
FR: The flow rate switch of the primary or secondary side has not detected any flow rate.
 
  
The heat pump is switched off because the operating mode, 2nd heat generator (HG2), was
selected. Heat generation is provided by the 2nd heat generator.
  
 
Flow rate monitoring of the heating water takes place before evaporator defrosting is started. This
applies to air-to-water heat pumps only. This process lasts a maximum of 4 minutes.

 
The heat pump defrosts the evaporator. This process lasts a maximum of 8 minutes.
  
 
The maximum flow temperature was overshot. Once the temperature drops, the HP will start again
automatically (HT HP only).

  
Switching to and from the cooling operating mode activates a time delay of 5 minutes. The heat
pump remains switched off during this period.
 
 
Despite a pending request, the chiller is unable to cool because frost protection was activated.
This state is ended automatically.
 
 
Despite a pending request, the chiller is unable to cool because the current flow temperature is
under the operating limit. This state is ended automatically.
  
 
Despite a pending request, the chiller is unable to cool because the dew point monitor was
activated (external input). This state is ended automatically.
 
 
Despite a pending request, the chiller is unable to cool because the dew point calculated from the
sensor values from the room climate control stations was undershot. This state is ended
automatically.
 
 
The heat pump operates in passive cooling and no requests are pending.
 

The external temperature is below the permissible cooling temperature limit.

Other manuals for Dimplex WPM 2007 R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dimplex WPM 2007 R and is the answer not in the manual?

Dimplex WPM 2007 R Specifications

General IconGeneral
BrandDimplex
ModelWPM 2007 R
CategoryNetwork Router
LanguageEnglish

Related product manuals