NOTE
Heating request
A heating request is pending if the “Return set temperature” minus the
“Hysteresis return temperature” is higher than the currently measured
“Return temperature”.
 

Displays the temperature measured on the “Antifreeze Cool”
sensor.
This temperature is used to safeguard the operating limits in
cooling operation.
Reversible HP
Cooling operation
  
 
Displays the current room set temperature with silent cooling. Cooling function
Silent cooling
Cooling operation
  
Displays the temperature measured in the room in which room
climate control station 1 is installed.
This temperature is the controlled variable for silent cooling.
Cooling function
Silent cooling
or
reference room
  
Displays the humidity measured in the room in which room climate
control station 1 is installed. This value is used for calculating the
dew point with silent cooling.
Cooling function
Silent cooling
  
Displays the temperature measured in the room in which room
climate control station 2 is installed.
This value is used for calculating the dew point with silent cooling.
Cooling function
Silent cooling
2 room stations
  
Displays the actual humidity in the room in which room climate
control station 2 is installed. This value is used for calculating the
dew point with silent cooling.
Cooling function
Silent cooling
2 room stations


Indicates if a request for cooling has been made Cooling function
Cooling operation
  
 
Displays the current hot water set temperature Domestic hot
water
Sensor
  
Displays the measured hot water temperature. This temperature is
the controlled variable for DHW preparation.
Domestic hot
water
Sensor
  

Indicates if a request for domestic hot water has been made. Even
if there is a request for hot water, it is possible that the heat pump
will not operate (e.g. because of the utility company shut-off time).
An HP block combined with a sufficiently high cylinder temperature
is indicated by “Bivalent-regen.”.
Domestic hot
water
 

Indicates if a request for swimming pool water has been made.
Even if there is a request for swimming pool water, it is possible
that the heat pump will not operate (e.g. because of the utility
company shut-off time). An HP block combined with a sufficiently
high cylinder temperature is indicated by “Bivalent-regen.”.
Swimming pool
  

Displays the temperature measured at the heat source output or
the refrigerating circuit output of the HP. This temperature serves
to safeguard the lower operating limit.
BW or WW HP
with integr.
controller

Displays the heat pump type identified from the coding resistor. At all times
 
Displays the heating controller software version including the boot
and bios version, as well as the valid network address.
At all times
 
Displays the cooling controller software version including the boot
and bios version, as well as the valid network address.
Cooling function
 
Displays whether a cooling controller is available in the network
(Contr. Cooling) and whether the network is operating correctly
(Network O.K.).
Cooling function
  Display of sensor and system values Display

Other manuals for Dimplex WPM 2007 R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dimplex WPM 2007 R and is the answer not in the manual?

Dimplex WPM 2007 R Specifications

General IconGeneral
BrandDimplex
ModelWPM 2007 R
CategoryNetwork Router
LanguageEnglish

Related product manuals