Low Voltage Landscape Transformers
User Manual
Important: Read all instructions prior to installation.
LVT-xW-12VAC
LVT-120W-12VAC
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Rev Date: V1 07/22/2019
Safety and Notes
Specications
Product should be installed and serviced in accordance with applicable national, state, and local building
and electrical codes.
Risk of re or electrical shock. Install transformer at least 10 ft (3.05 m) from pools, spas, or fountains.
Outdoor, above ground installation only. For use with low voltage landscape lighting only.
This transformer must be connected to GFCI-protected receptacle marked suitable for wet locations.
Receptacle must be protected by a weatherproof cover.
Do not submerge the transformer or use it to power submersible lights or lights mounted in or near pools,
spas, or fountains.
If cleaning is necessary, use a damp cloth to wipe down case. Do not spray transformer with pressurized
water or steam.
Do not use with a dimmer or extension cord or attempt to wire in parallel with other transformers.
Do not exceed 70% of the maximum wattage of the transformer when connecting lights.
Transformer must be mounted in a vertical orientation with the bottom at least 1 ft from the ground.
Ensure all mounts are securely attached and will support the transformer’s weight. Failure to properly
support transformer may result in damage or injury, for which the manufacturer does not assume responsibility.
Do not attempt to disassemble or modify transformer.
Ensure wire to lights is correct gauge for the run and total power of the intended circuit and is intended for use
with outdoor landscape applications.
Mounting Transformer
To function properly, transformer should be installed in a location
where photocell is not blocked or too near nighttime light sources.
Securely mount transformer 1–4 ft from ground level using a
weather resistant screw that is an appropriate size to support
transformer’s weight.
Model LVT-60W-12VAC LVT-120W-12VAC LVT-200W-12VAC
Input Voltage 120 VAC
Input Current 600 mA (0.6 A) 1,200 mA (1.2 A) 2,000 mA (2 A)
Output Voltage 12 VAC
Output Current 5 A 10 A 16.7 A
IP Rating IP54
Warranty 3 years
Model LVT-60W-12VAC LVT-120W-12VAC LVT-200W-12VAC
Max. Screw
Diameter
3/16” (5 mm) 1/4” (6 mm) 9/32” (7 mm)
Mount
Rear View
Question and Answer IconNeed help?

Do you have a question about the DiodeDrive LVT-W-12VAC Series and is the answer not in the manual?

Summary

Low Voltage Landscape Transformers

Specifications

Details the electrical specifications for the transformer models, including input/output voltage and current.

Safety and Notes

Provides crucial safety precautions and usage guidelines for installation and operation to prevent hazards.

Mounting Transformer

Instructions and requirements for securely mounting the transformer unit in a vertical orientation.

Troubleshooting

Guidance for diagnosing and resolving common issues like overloads or display problems.

Connecting to Landscape Wiring

Steps for properly preparing and connecting landscape wiring to the transformer terminals.

Timer Controls and Display

Explanation of the transformer's timer functions, display indicators, and control buttons.

System Check

Procedure for verifying proper installation and connection integrity by checking connection temperature.

Overview

This document describes the Low Voltage Landscape Transformer, a device designed for outdoor landscape lighting applications. It functions by converting standard 120 VAC input power to a safe 12 VAC output, suitable for low voltage lighting systems.

Function Description:

The transformer's primary function is to provide a stable 12 VAC power source for landscape lighting. It includes a digital timer and photocell for automated operation, allowing users to set the lights to turn on at dusk and off at dawn, or to operate for a specific number of hours after dusk. The device is designed for outdoor, above-ground installation only and must be connected to a GFCI-protected receptacle suitable for wet locations. A key safety feature is its ability to cut output power in the event of a significant overload, protecting both the transformer and the connected lighting system.

Important Technical Specifications:

  • Models: LVT-60W-12VAC, LVT-120W-12VAC, LVT-200W-12VAC
  • Input Voltage: 120 VAC for all models.
  • Input Current:
    • LVT-60W-12VAC: 600 mA (0.6 A)
    • LVT-120W-12VAC: 1,200 mA (1.2 A)
    • LVT-200W-12VAC: 2,000 mA (2 A)
  • Output Voltage: 12 VAC for all models.
  • Output Current:
    • LVT-60W-12VAC: 5 A
    • LVT-120W-12VAC: 10 A
    • LVT-200W-12VAC: 16.7 A
  • IP Rating: IP54, indicating protection against dust ingress and splashing water.
  • Warranty: 3 years.
  • Max. Screw Diameter for Mounting:
    • LVT-60W-12VAC: 3/16" (5 mm)
    • LVT-120W-12VAC: 1/4" (6 mm)
    • LVT-200W-12VAC: 9/32" (7 mm)

Usage Features:

  • Installation:
    • Must be installed at least 10 ft (3.05 m) from pools, spas, or fountains.
    • Outdoor, above-ground installation only.
    • Connects to a GFCI-protected receptacle suitable for wet locations, which must be protected by a weatherproof cover.
    • Mounting: Securely mount 1-4 ft from ground level in a vertical orientation, with the bottom at least 1 ft from the ground. The photocell should not be blocked or too near nighttime light sources.
    • Wiring: Remove approximately 0.5 inches of insulation from landscape wiring, insert wires fully into the terminal plate, and tighten securely.
    • Do not exceed 70% of the transformer's maximum wattage when connecting lights.
    • Ensure the wire gauge to lights is correct for the run and total power of the intended circuit.
  • Timer Controls and Display:
    • Display On/Off: The display is lit when there is power on the output side. It may be off if the transformer is overloaded or if the 1-9 timer settings have turned off output power.
    • Constant Power Mode (P): Indicated by 'P' on the display, meaning the transformer output stays on 24 hours a day.
    • Dusk-to-Dawn Mode (A): Selecting 'A' puts the transformer in automatic dusk-to-dawn mode, turning output power on at dusk and off at dawn.
    • Timed Operation (1-9): Selecting a number from 1 to 9 switches output power on at dusk and off after the selected number of hours.
    • Overload Indication (Flashing L): 'L' flashes when the transformer detects a minor overload.
  • Safety Precautions:
    • Do not submerge the transformer.
    • Do not use it to power submersible lights or lights mounted in or near pools, spas, or fountains.
    • Do not use with a dimmer or extension cord.
    • Do not attempt to wire in parallel with other transformers.
    • Do not attempt to disassemble or modify the transformer.

Maintenance Features:

  • Cleaning: If necessary, use a damp cloth to wipe down the case. Do not spray the transformer with pressurized water or steam.
  • Troubleshooting Overload: If the display is off due to an overload, fix the issue (e.g., reduce connected wattage, check for short circuits in wiring), then press the up arrow on the digital timer controls to restart the transformer.
  • System Check: After installation, operate the system for five minutes. Connections should be cool to the touch. If a connection is hot, re-tighten it and check for temperature decrease.