3
N506T 12-02
© 2002 Directed Electronics, Inc.
A
dding a 506T to a DEI system with a shock sensor port and an on-board shock sensor
To add a 506T to a DEI system with a shock sensor port and an on-board shock sensor, refer to the configura-
tion diagram below and follow these steps:
1. Plug the microphone into the 506T.
2. Plug the 3-wire audio sensor harness (with the blue, red, and black wires) into the 506T.
3. Plug the 4-wire main harness (with the red, black and two blue wires) into the shock sensor port of the DEI
alarm.
4. Cut or tie remaining harness wires.
5. Adjust and test the audio sensor before mounting.
In most DEI systems with on-board shock sensors, the on-board shock sensor will report Zone 2, and the 506T
will report Zone 4. (Refer to the Table of Zones section of the alarm system’s installation guide.)
AUDIO
MICROPHONE
506T AUDIO SENSOR