EasyManuals Logo

Directed Electronics Viper 5704 User Manual

Directed Electronics Viper 5704
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
© 2011 Directed Electronics. All rights reserved.
4. Siren Duration
1. 30sec: the siren output for full trigger activations and Panic mode is 30 seconds
2. 60sec: the siren output for full trigger activations and Panic mode is 60 seconds
5. Ign-controlled Locks
1. No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned on/off
2. Lock & Unlock: the door lock & unlock output will activate when ignition is turned on & off
3. Lock Only: the door lock output will activate when ignition is turned on
4. Unlock Only: the door unlock output will activate when ignition is turned off
6. Door Lock Pulses
1. Single: the door lock & unlock outputs will pulse once
2. Double Unlock only: the unlock output only will pulse twice
3. Double Lock Only: the lock output only will pulse twice
4. Double Lock & Unlock: the lock & unlock outputs will pulse twice
7. Door Lock Output Duration
1. 0.8 sec.: the door lock output pulses will be 800 ms in duration
2. 3.5 sec.: the door lock pulses will be 3.5 seconds in duration
3. 0.4 sec.: the door lock pulses will be 400 ms in duration
8. Ignition Controlled 2nd Unlock
1. After first unlock: for Ign-controlled unlocking, the 2nd unlock will activate 800 ms after the first (driver
door) unlock
2. With first unlock: for Ign-controlled unlocking, the 2nd unlock will activate at the same time as the first
(driver door) unlock
9. Comfort Closure
1. No comfort Closure: Comfort Closure is defeated when arming
2. Comfort Closure 1: the door lock pulse (or 2nd pulse for double pulses) will remain on for 20 sec-
onds.
3. Comfort Closure 2: 800 ms following the end of the door lock pulse (or 2nd pulse for double pulses);
the door lock output will turn on again for 20 seconds.
10. Horn Function
1. Full Alarm Only: the horn output will pulse only during full trigger events.
2. Siren Function 20/30/40/50ms: The horn output will emulate the siren output with selectable chirp
output timing to compensate for OEM horn inefficiency.
11. Hood Switch Type
1. Normally Open: for vehicles with a hood switch that rests at ground when the hood is OPEN
2. Normally Closed: for vehicles with a hood switch that rests at ground when the hood is CLOSED
12. Sensor Full Trigger
1. Single: full trigger activation of only one sensor is required to fully trigger the alarm
2. Double: full trigger activation of two sensors within a ten second period is required to fully trigger
the alarm.
13. Door Switch Type
1. Normally Open: for vehicles with door switches that rest at ground when the door is OPEN
2. Normally Closed: for vehicles with door switches that rest at ground when the door is CLOSED
14. Trunk Switch Type
1. Normally Open: for vehicles with a trunk switch that rests at ground when the trunk is OPEN
2. Normally Closed: for vehicles with a trunk switch that rests at ground when the trunk is CLOSED
15. Remote Button Unlock (Ign off)
1. On: a message telling the remote control to unlock the keypad is sent each time the vehicle ignition
is turned off
2. Off: no message is sent

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Directed Electronics Viper 5704 and is the answer not in the manual?

Directed Electronics Viper 5704 Specifications

General IconGeneral
BrandDirected Electronics
ModelViper 5704
CategoryCar security system
LanguageEnglish

Related product manuals