Specifications - 80 SK600 Operator’s Manual
SK600
Specifications are called out according to SAE recommended practices. Specifications are general and subject to change without
notice. If exact measurements are required, equipment should be weighed and measured. Due to selected options, delivered
equipment may not match that shown.
Hydraulic System US Metric
Auxiliary: double gear pump
Flow rate (pump 1) 6.0gpm 22.7L/min
Flow rate (pump 2) 6.0gpm 22.7L/min
Pressure 3000psi 207bar
Ground drive: dual hydrostat
Flow rate 12.5gpm 47.2L/min
Pressure 3625psi 250bar
Fluid Capacities US Metric
Fuel tank 10.5gal 40L
Engine oil, with filter 3.9qt 3.7L
Hydraulic reservoir 9.2gal 35L
Battery
SAE reserve capacity 85min, SAE cold crank @ 0°F (-18°C) 525amp, 12V electrical system
Vibration Levels
Average vibration transmitted to the operator’s hand during normal operation with a loader bucket is
6.5m/sec
2
. Average vibration transmitted to the whole body during normal operation with a loader
bucket is 0.81m/sec
2
. Actual vibration will depend on the attachment being used.
Noise Level
This machine can generate sound levels exceeding 80dBA. Always wear appropriate hearing protection
when operating machine. Find sound power and pressure information at www.ditchwitch.com, or
contact customersupport@ditchwitch.com.