Thank you for your freezer purchase. Your digital temperature controller should arrive pre-set to factory
standards. This manual is provided to assist with any small changes you may wish to make. If you are
experiencing any issues with the function of your cooler, we are available for support at
service@ironmountainrefrigeration.com or by phone at 833-734-8880.
Your freezer is designed to maintain a temperature range with a high and low setting. When the high
temperature is reached, the compressor will start and run until the low temperature is reached. Setting
the high and low too close may cause ice build up and compressor failure.
To see your set temperature, press and release “SET”. To change it, hold “SET” until F is flashing and use
up or down to adjust. This temperature must be within the selected temperature range in the
parameters. To check or adjust the parameters, follow the steps below.
1. Hold “Set” and “Down together for 3 seconds until F is flashing. Release. Hold Set” and
Downagain for 10 seconds until L2” is shown.
2. You are now in the parameter menu. The first parameter, “Hy is shown.
a. Press Set to see the current setting.
b. Use Up and Down arrows to change, if needed.
c. Press “Set” to show next parameter.
3. To exit and save changes, press Set” and “Up” together.