Accuracy | ±1°C |
---|---|
Hysteresis | Adjustable |
Probe Inputs | NTC or PTC |
Digital Inputs | 1 configurable |
Display | 3 digits LED |
Probe Type | NTC |
Enclosure Rating | IP65 |
Temperature Range | -50°C to +110°C |
Manual is part of the product and should be kept near the instrument for easy and quick reference.
Check supply voltage, avoid water/moisture, disconnect electrical connections before maintenance.
Regulation based on thermostat probe differential. Start/stop timed if probe fails.
Two modes (electrical heater, hot gas). Controlled by 'tdF' parameter. Defrost end by evaporator probe.
Accesses installer parameters ('Pr2') requiring a security code (321).
Step-by-step guide to modify parameter values using 'SET', 'UP', 'DOWN' keys.
Configures how temperature alarms relate to SET point or absolute values.
Sets defrost duration or maximum length based on EdF.
Sets evaporator probe temp for defrost termination (when EdF=1).
Selects defrost method (electrical heater, hot gas, etc.).
Selects fan operation mode (with/without compressor, continuous).
Adjusts possible offset of the thermostat probe.
Adjusts possible offsets of the evaporator probe.
Indicates data or memory failure. Includes steps for troubleshooting.