7
EN
Getting Started
Filling Engine Oil
The generator has not been lled with engine oil before leaving the factory. It is necessary to add engine oil
before use.
Place the generator on a flat and stable surface, unscrew the dipstick, fill the engine with oil to the rated
capacity, and screw the dipstick back on. The D6000i Multifunctional Inverter Generator has a rated engine oil
capacity of 0.8 L. Use SJ 10W-40 engine oil (or equivalent).
Refueling
Fuel is highly ammable and explosive. Strictly follow the instructions to use. Before refueling the generator,
power it o and wait until it has completely cooled down.
1. Loosen the fuel tank cap and refuel the fuel tank with the recommended type of fuel to the rated capacity
according the oil level gauge*. The D6000i Multifunctional Inverter Generator has a rated fuel capacity of 20 L.
2. Tighten the fuel tank cap after refuelling. Use a dry towel to wipe up if any fuel is spilled.
* For recommended fuel types for dierent countries and regions, refer to the Appendix section.
• Make sure to turn the fuel valve to the OFF position before refueling or after stopping the generator.
• DO NOT overll fuel. Spilling can lead to a re or explosion.
• Using ethanol fuel may increase the fuel consumption.
Pre-Operation Checking
In order to ensure your safety and preserve the service life of the generator, take some time to check the
conditions of the generator before each operation. Make sure any issues or malfunctions have been resolved
before operation.
Before starting the pre-operation check, make sure the generator is placed on a stable place and the engine
switch is in the OFF position.
Common Check-Up Items
1. Check whether there is any spilled engine oil or fuel around or under the generator.
2. Remove any ammable materials in the surrounding area especially around the muer and the fan hood.
3. Repair or replace any rusted, broken, damaged, deformed, or loosened parts.
4. Check whether the muer shield and the fan hood have been securely installed in place and whether all the
nuts, bolts, and screws have been tightened.
USB-C Cable
USB-C Connector on the Generator
USB-A Connector on the
Remote Controller