EasyManua.ls Logo

DMEGA Mega Power I - Annual Maintenance

DMEGA Mega Power I
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mega Power -
Liquid Ring Vacuum Pump
8
Every 1 year Maintenance Clean Water Inlet strainer (Y- type)
If main tap water condition is not clean, check the water inlet strainer if
necessary or every 1 year.
The water inlet strainer has small wire mesh inside to remove rust.
Use large crescent wrench to remove nut. With air gun clean mesh inside of
strainer and then re-assemble. The nut should be tightened not to be leaks.
Cleaning filter (Every week)
Cleaning water inlet strainer (If necessary or every 1 year)