( Model : Mega Power I )
Caution: Use this Liquid ring vacuum pump Only for its intended use as
described in this
manual. Improper use or failure to do so could result in
personal injury or property damage. This device is to only be used by
dental staff or dentist in dental practice.
REV0.08.13.15
Mega Power I
®
Liquid Ring Vacuum Pump
Instruction Guide
Question and Answer IconNeed help?

Do you have a question about the DMEGA Mega Power I and is the answer not in the manual?

Summary

Product Structure

Explosive View of Product

Diagram illustrating the assembly of product components for identification.

Included Accessories

Important Safeguards

Product Cautions

Precautions related to electrical shock, modification, and usage environment.

Operating Cautions

Guidelines for safe operation, including connections and handling abnormalities.

Storage Cautions

Recommendations for storing the unit to prevent damage and ensure longevity.

Device Specifications

Installation Instructions

Plumbing Diagram

Visual representation of the water and exhaust line connections for the vacuum pump.

Maintenance

Daily Maintenance

Routine cleaning procedures for the vacuum piping system.

Weekly Maintenance

Procedure for cleaning the in-line filter and associated components.

Annual Maintenance

Wiring Diagram

Trouble Shooting

Part List

Warranty

Details and Period

Details the warranty coverage period and conditions for the product.

Exceptions for Warranty

Lists conditions and faults that are not covered under the product warranty.

Notice

Important notices regarding warranty validation, contact information, and usage guidelines.

Summary

Product Structure

Explosive View of Product

Diagram illustrating the assembly of product components for identification.

Included Accessories

Important Safeguards

Product Cautions

Precautions related to electrical shock, modification, and usage environment.

Operating Cautions

Guidelines for safe operation, including connections and handling abnormalities.

Storage Cautions

Recommendations for storing the unit to prevent damage and ensure longevity.

Device Specifications

Installation Instructions

Plumbing Diagram

Visual representation of the water and exhaust line connections for the vacuum pump.

Maintenance

Daily Maintenance

Routine cleaning procedures for the vacuum piping system.

Weekly Maintenance

Procedure for cleaning the in-line filter and associated components.

Annual Maintenance

Wiring Diagram

Trouble Shooting

Part List

Warranty

Details and Period

Details the warranty coverage period and conditions for the product.

Exceptions for Warranty

Lists conditions and faults that are not covered under the product warranty.

Notice

Important notices regarding warranty validation, contact information, and usage guidelines.

Overview

The Mega Power I® Liquid Ring Vacuum Pump is a dental suction unit designed to extract contaminated water from dental units. This instruction guide provides comprehensive information for its proper installation, operation, and maintenance, emphasizing safe and effective use in a dental practice setting.

Function Description

The primary function of the Mega Power I® is to provide dental suction, specifically to draw contaminated water from dental units. It operates as a liquid ring vacuum pump, utilizing a rotating impeller within a liquid (typically water) to create a vacuum. This vacuum then facilitates the removal of fluids and debris generated during dental procedures. The system incorporates a line filter to prevent larger particles from entering the pump, a solenoid valve to control water flow, and an exhaust separator to manage the discharge. The overall design aims to ensure efficient and reliable suction for a clean and safe dental environment.

Usage Features

The Mega Power I® is designed for straightforward operation, with several features contributing to its ease of use and safety:

  • Intended Use: This suction unit is exclusively intended for dental suction applications, specifically for removing contaminated water from dental units. Adherence to this intended use is crucial for preventing personal injury or property damage.
  • Installation: The manual provides detailed installation steps, including checking the shipping carton for damage, inspecting the unit, proper placement, connecting inlet and outlet hoses with clamps for a tight seal, and connecting the remote control cable to the pump relay cable on the PCB. After installation, users are instructed to turn on the vacuum pump power switch and check for any leakage or issues with the vacuum level.
  • Safety Precautions: The guide highlights several important safeguards. Users are cautioned to read all instructions carefully before use, as improper use can lead to personal injury or equipment damage. Modifications to the equipment are explicitly stated to void the warranty. Key product cautions include keeping the unit away from water to avoid electrical shock, never operating a damaged unit or one that has been dropped or submerged, and avoiding use in areas with flammable gas, oxygen, or aerosol spray products. Disconnecting the unit from the electrical outlet before cleaning or maintenance is also emphasized.
  • Operating Cautions: Users are advised to connect the product to an appropriate voltage outlet, avoid running it unattended, discontinue use immediately if any abnormality occurs, and always power off the product after use.
  • Storage Cautions: To ensure longevity and proper function, the unit should not be stored under direct sunlight, extreme temperatures, or high humidity. Wet storage areas should be avoided, and the unit should always be powered off with water connections closed when not in use.

Maintenance Features

Regular maintenance is critical for the optimal performance and longevity of the Mega Power I® vacuum pump. The manual outlines a clear maintenance schedule:

  • Daily Maintenance – Clean Vacuum Piping System: The vacuum piping system should be cleaned daily using a non-foaming vacuum system cleaner. This routine helps prevent blockages and maintains efficient suction.
  • Weekly Maintenance – Clean In-Line Filter: The in-line filter requires weekly cleaning. This involves turning off the pump motor, carefully unscrewing the lower bowl (clockwise to loosen), lifting out the screen, and removing the screen and gasket. Both the screen and gasket should be cleaned, and the gasket lubricated with water. Contaminated sediment and disinfectant solution waste must be disposed of properly. Before reassembling, users must ensure the gasket is in place. All connecting vacuum, waste, and water lines should be checked for tightness.
  • Every 1 Year Maintenance – Clean Water Inlet Strainer (Y-type): If the main tap water condition is not clean, or at least once a year, the water inlet strainer (Y-type) should be checked and cleaned. This strainer contains a small wire mesh to remove rust. Users are instructed to use a large crescent wrench to remove the nut, clean the mesh inside the strainer with an air gun, and then re-assemble, ensuring the nut is tightened to prevent leaks.
  • Troubleshooting Guide: A comprehensive troubleshooting chart is provided to assist users in identifying and resolving common issues. This chart lists potential problems (e.g., motor not starting, motor stopping, low or no vacuum, pump leaking), possible causes (e.g., loose wires, clogged filters, faulty solenoid valve, insufficient water supply), and corresponding solutions (e.g., replacing fuses, cleaning filters, tightening connections, replacing parts). This guide empowers users to perform basic diagnostics and corrective actions, reducing downtime and the need for professional service for minor issues.
  • Warranty Information: The product comes with a 24-month warranty from the date of purchase, covering defects in material and workmanship under normal use. The manual specifies conditions for warranty validity, exceptions (e.g., misuse, lack of maintenance, unauthorized repairs, natural disasters, missing warranty card), and instructions for obtaining warranty service. Customers are responsible for freight charges to DMEGA for warranty claims.

DMEGA Mega Power I Specifications

General IconGeneral
Power800 W
Frequency50Hz
Inlet/Outlet Size1.5 inches
Voltage230V
Inlet/Outlet Diameter1.5 inches