EasyManua.ls Logo

DMG Pitagora 4.0 - System Status and Faults Monitoring

DMG Pitagora 4.0
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
“System Status” Menu
It is easily accessed from the main window of the PlayPad, by pressing once the ENTER key.
Doors
▲ ▼
Signals
▲ ▼
Special functions
▲ ▼
Positioning
▲ ▼
VVVF
▲ ▼
Rec.Parameters
▲ ▼
Clock
After selecting the desired language Is necessary to perform the software Upgrade (Annex III)
System Status Description
Visualization
on
Serial display
Resetting The system is performing the reset procedure O -
In service The system is in normal operation mode
Inspection The system is in inspection mode OR
Temp. Operat The system is in temporary operations mode P
Out of service The system is out of service
Car Priority
The system is running in elevator car priority mode (priority key switch
activated)
Fire-fighters The system is operating in Fire-fighters mode (various operations)
Emergency The system is performing the emergency procedure E
Drift control The system is performing the elevator car drift control procedure
Upward operation The system is running upwards
Downward
operation
The system is running downwards
Re-levelling The elevator car is at floor level and is re-levelling
Still at floor The elevator car is at floor level, with no registered calls
Reference table