Cod. Parameter Description Navigation Values
Default
Value
F20
DC Brake
speed
Frequency threshold for DC
INJECTION
◄►
(Selection)
▲▼
(Change
value)
1,0 Hz
F21
DC Brake
level
Intensity threshold for DC INJECTION
◄►
(Selection)
▲▼
(Change
value)
45 %
F22
DC Brake
T
DC INJECTION time
◄►
(Selection)
▲▼
(Change
value)
0,8 sec
F23
Starting
Speed
Starting speed (in Hz) for the inverter
◄►
(Selection)
▲▼
(Change
value)
0,00-150
0,5 Hz
(FAI/FAS)
0,1 Hz
(Encoder)
F24
Holding
Time
Holding time of running at starting
speed for the inverter
◄►
(Selection)
▲▼
(Change
value)
0,00-10 Sec
0,0 sec
(FAI/FAS)
0,3 sec
(Encoder)
F25
Stopping
Speed
Stopping speed (in Hz) for the inverter
◄►
(Selection)
▲▼
(Change
value)
0,0 Hz
(FAI/FAS)
0,1 Hz
(Encoder)
F26
Motor
Sound
Carrier frequency
◄►
(Selection)
▲▼
(Change
value)
15 KHz
F42
Control
Mode
Control Mode
◄►
(Selection)
▲▼
(Change
value)
0-1-2
0 (Geared
drives,
closed loop)
1 (Gearless
drives,
closed loop)
2 (Geared
drives, open
loop)