Annex 2 – Test and measures
The main switch of the controller must be switched off by every maintenance and at least 365 days after the last
switch off and on.
This procedure is mandatory and must be followed in order to start the Autotest of the ELGO LIMAX CP33 and
FUJI LM2 components.
standard) and the call must go to the bigger elevator car.
Example 8
Controller A floors Controller B floors
5
4
5 3
4 2
3 1
2 0
1
0
If this function is activated, two types of call are possible:
a) standard pressure call (the call is assigned to the nearest elevator);
b) long pressure call (more than 3 seconds of pressure); this call is assigned to the elevator which can reach the
highest floor (UP call) or the lowest (DOWN call). The example shows a long pressure call always being assigned to
controller A, whereas a long pressure UP call will always be assigned to controller B.
The following tests and measures may facilitate controls and tests to be performed before putting the installation in
service (EN81-X D) and during the periodic maintenance interventions (EN81-X E). Some measures can be
performed only through the encoder counting system.
Tests can be performed only if the installation is in normal operation mode; select parameter “test” to perform the test
and press ENTER to start it. The test procedure can be stopped by switching the installation to inspection mode.
Test 1: Measure of the stopping space and time in UP direction, DMG UCM module in acceleration out of the
door zone
Before starting the test, move the empty elevator car to the floor where you want to take the measure.
During the test, the elevator car will move upwards until the end of that floor door zone; now the forced intervention of
the UCM module is activated and the elevator car will thus stop. After the elevator car has stopped, the distance
covered from the floor level is shown (to be compared to point 9.11.5 of EN81) and the stopping time since the UCM
activation. Important: the stopping distance must be calculated before, considering the sum of intervention times
(controller + stopping unit). After the test, the UCM module must be reset (menu <Faults> reset UCM).
Test and measures (first part)