Do you have a question about the DOLD Safemaster LG 5925 and is the answer not in the manual?
Category | 4 |
---|---|
Rated operational current | 6 A |
Mounting type | DIN rail |
Supply voltage | 24V DC / 230V AC |
Auxiliary contacts | 1 NC |
Stop Category | 0 |
Standards | EN 60204-1 |
SILCL | SIL 3 |
Rated operational voltage | 24V DC / 230V AC |
Mechanical life | 10 million operations |
Electrical life | 100, 000 operations at rated load |
Operating temperature range | -25°C to +55°C |
Protection class | IP20 |
Explains symbols used for warnings and information within the manual.
Provides general product information, intended application scope, and potential residual risks.
Details critical safety precautions for electrocution, fire, functional errors, and installation faults.
Illustrates device operation, internal structure, and control logic for safety functions.
Lists product certifications, typical application uses, and status indicator meanings.
Shows various wiring configurations for emergency stop circuits and safety gate monitoring.
Explains specific functionalities like line fault detection and switch operations for circuit configuration.
Details the purpose of each terminal and its signal assignment for wiring.
Specifies contact ratings, switching frequency, and electrical endurance of the device.
Covers operating temperature, altitude, EMC, protection degree, and vibration resistance.
Provides UL specific data and information on standard product types and their listings.
Illustrates the format for specifying product variants and options when ordering.
Lists common issues, potential causes, and recommended solutions for device malfunction.
Addresses maintenance requirements and presents characteristic curves for performance analysis.
Demonstrates single-channel and 2-channel emergency stop circuits with contact reinforcement.
Shows 2-channel E-stop with cross fault detection and safety gate monitoring applications.
Displays device labeling and connection diagrams for different terminal types.
Details specifications for PS and PC terminal blocks and compatible wire gauges.
Provides physical dimensions and instructions for device setting and programming.
Explains the steps for mounting the device and removing terminal blocks.
Presents safety performance level, category, and MTTF data according to EN ISO 13849-1.
Details SIL classification, HFT, and PFDavg according to IEC/EN 62061 standards.
Clarifies data validity for standard types and system-level safety determination.
Declares product conformity with relevant EU directives like Machinery, EMC, and RoHS.
Lists the standards used for testing and the details of the notified certification body.