3. Turn the cooling level controller (fig. 4 1, page 4 and fig. 5 1, page 5) to the
required position.
The cooler starts cooling the interior.
6.6 Connecting the cooler to a gas supply
!
A
Connecting the cooler to an external gas connection socket (ACX3 30 and
ACX3 40)
!
Proceed as follows (fig. 8, page 6):
1. Perform a visual inspection of the hose (for cracks, weathering, damage).
!
2. Place the cooler on a firm, level surface.
WARNING!
Only use approved hoses (DIN 4815, part 2) with a maximum length
of 1.5 m.
The cooler may only be operated with hoses in a perfect technical
condition.
Replace the hose when it is porous or when the national conditions
require it.
NOTICE!
Only use cylinders of propane or butane gas (not natural gas or city
gas) with an approved pressure reduction valve and suitable head.
Compare the pressure information on the type plate with the
pressure information on the pressure regulator on the propane or
butane gas cylinder.
Observe the pressures which are permitted in your country. Use a
DIN-DVGW-approved pressure regulator with a fixed setting:
The following applies for Germany: DIN EN 16129.
The following applies for Europe: EN 732, EN 521 and
EN 437:2019-04.
WARNING!
There must be a shut-off device in the gas line so that the cooler can be
cut off separately. The shut-off device must be easily accessible.
WARNING!
Replace the hose when it is porous or when the national conditions
require it.