EasyManua.ls Logo

Dometic CD20 - Page 14

Dometic CD20
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Troubleshooting CD20, CD30
16
Interior temperature too low in the “MIN” thermostat setting
During attempted start
up U
Ter m
U
OFF
Loose cable connection
Poor contact (corrosion)
Establish a connection
Cable cross section too small Replace the cable
(fig. 6, page 5)
Battery capacity too low Replace the battery
During attempted start
up U
Ter m
U
ON
Ambient temperature too high
Insufficient ventilation and/or air
supply
Move the refrigerator to
another location
Condensor is dirty Clean the condenser
Electric circuit between
the pins in the
compressor interrupted
Defective compressor Replace the compressor
U
Ter m
Voltage between the positive and negative electronic terminals
U
ON
Switch on voltage of the electronic connection terminals
(see chapter “Technical description” on page 10)
U
OFF
Switch off voltage of the electronic connection terminals
(see chapter “Technical description” on page 10)
Feature Possible cause Remedy
Compressor runs con-
tinuously
Thermostat sensor has no contact to the
vaporiser
Secure the sensor
Short circuit in the thermostat line Change the thermo-
stat
Thermostat defective
Compressor runs for a
long time
Large quantities have been frozen in the
vaporiser compartment
Feature Possible cause Remedy
CD20-30-IO-16s.book Seite 16 Dienstag, 14. März 2017 1:56 13

Other manuals for Dometic CD20

Related product manuals