Refrigerator
Installation and Operating Manual. . 10
Kühlschrank
Montage- und Bedienungs-
anleitung . . . . . . . . . . . . . . . . . . . . . 31
Réfrigérateur
Instructions de montage
et de service . . . . . . . . . . . . . . . . . . 52
Nevera
Instrucciones de montaje y de uso . 75
Frigorífico
Instruções de montagem e manual de
instruções . . . . . . . . . . . . . . . . . . . . 97
EN
DE
FR
ES
PT
CRX1050, CRX1065,
CRX1080

Table of Contents

Questions and Answers

  • O
    ocampbellJul 28, 2025
    Why is my Dometic CRX 1050 not cooling properly?
    • M
      Matthew KingJul 29, 2025
      If your Dometic Refrigerator isn't cooling well and the interior temperature is rising, it could be due to several reasons. The ambient temperature might be too high. Insufficient ventilation could also be the cause, so try moving the refrigerator to a different position. A dirty condenser can also lead to poor cooling, so cleaning it might help. Check the fan; a faulty fan should be replaced. Also, ensure the battery is charged, as an exhausted battery capacity can affect cooling performance.
  • R
    Randy WhiteAug 12, 2025
    How to fix a Dometic CRX 1050 Refrigerator compressor that won't run on AC supply?
    • M
      Megan BryantAug 12, 2025
      If your Dometic Refrigerator's compressor isn't running when connected to an AC supply, several factors could be responsible. Ensure the connection supply line isn't interrupted, and establish a connection if it is. If installed, the main switch might be faulty and need replacement. Check for a blown additional supply line fuse and replace it if necessary. Also, consider whether the ambient temperature is too high, or if there's insufficient ventilation; in the latter case, move the refrigerator to a different position. A dirty condenser can also cause this issue, so clean it. Finally, if the electric circuit between the pins in the compressor is interrupted, the compressor will need to be replaced.
  • S
    Scott HodgeSep 10, 2025
    Why is my Dometic Refrigerator making unusual noises?
    • M
      meyersedwardSep 12, 2025
      Unusual noises from your Dometic Refrigerator can stem from a few sources. A component of the refrigerant circuit might be touching the wall; carefully bend it away from the obstruction. Alternatively, a foreign object might be stuck between the cooling unit and the wall; remove it. The noise might also be attributed to the fan.
  • K
    Katie GarnerNov 3, 2025
    What to do if the compressor of my Dometic Refrigerator does not run on battery?
    • J
      Jennifer CampbellNov 3, 2025
      If the compressor of your Dometic Refrigerator isn't running when connected to a battery, there are several potential causes. First, check if the connection between the battery and the electronics unit has been interrupted and establish a connection if needed. If installed, the main switch might be faulty and require replacement. Also, check if an additional supply line fuse has blown and replace it if necessary. Ensure that the battery voltage isn't too low by charging the battery. Look for loose cables or corrosion, and establish a connection if needed. Consider replacing the battery if its capacity is too low. If the cable cross section is too small, replace the cable. Ensure sufficient ventilation or move the refrigerator to a different position. Clean the condenser if it's dirty. If t...

Summary

Understanding Dometic Refrigerator Symbols

Dometic Refrigerator Safety Guidelines

General Safety Precautions for Dometic Refrigerators

Safe Operation of Dometic Refrigerators

Whats Included: Dometic Refrigerator Scope of Delivery

Optional Dometic Refrigerator Accessories

Intended Use of Dometic Refrigerators

Dometic Refrigerator Technical Overview

Internal Dometic Refrigerator Controls

External Dometic Refrigerator Control Panel

Dometic Refrigerator Installation and Connection Guide

Boat Installation Safety for Dometic Refrigerators

Safety guidelines specific to installing the refrigerator on boats.

Dometic Refrigerator Installation Steps

How to Change Dometic Refrigerator Door Hinge

Dometic Refrigerator Power Connection Guide

Using Your Dometic Refrigerator

Dometic Refrigerator Energy Saving Tips

Tips and recommendations for optimizing the energy efficiency of the refrigerator.

Dometic Refrigerator Operation Guide

Dometic Refrigerator Cleaning and Maintenance

Dometic Refrigerator Warranty Information

Dometic Refrigerator Disposal Guidelines

Dometic Refrigerator Troubleshooting Guide

Dometic Refrigerator Technical Specifications

Dometic CRX 1050 Specifications

General IconGeneral
TypeCompressor Refrigerator
Power Supply12/24 V DC
Input voltage (DC)12/24 V
Dimensions product depth500 mm
RefrigerantR134a
Energy classA+
Energy class EUA+
Rated input power (DC)54 W (12 V), 54 W (24 V)
ColorBlack