What to do in case of problems CT4000
30
8.5 Replacing the fuse in the operating unit
!
➤ Lift the control unit with a suitable tool and then pull it out of the bracket or wall
(fig. q, page 14).
➤ Replace the fuse (automotive fuse: 7.5 A) on the bottom of the control unit
(fig. q 1, page 14).
8.6 Replacing the wheels on the cassette tank
The wheels on the cassette tank can be replaced individually if required:
➤ Remove the old wheel as shown (fig. r, page 15).
➤ Mount the new wheel as shown (fig. r, page 15).
➤ Ensure that the wheel moves freely.
9 What to do in case of problems
Dometic offers a Europe-wide service network. Authorized customer service centres
are available on the Internet on the website dometic.com.
When contacting customer service, please make a note of the following information
on the type plate:
• Model Designation
• Product Number
• Serial No.
• MLC
I
CAUTION!
• Switch off the voltage supply before you start!
• Carefully pull the control unit out of the wall opening. There is a risk
of injury due to the springs springing back!
NOTE
You can find the type plate in the cassette housing after removal of the
cassette.
CT4000-O-WEST.book Seite 30 Donnerstag, 20. April 2017 11:53 11