EasyManua.ls Logo

Dometic H30 - Page 3

Dometic H30
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frequent enquiries
3
Q: Why is less water stored in water tank of the
dehumidifier in winter?
In winter temperature is low and air is dry. In co mp arison with summer,
the dehumidification ability of the dehumidifier decreases remarkably,
this is not a fault.
Q: Why the dehumidifier
running suddenly
cannot
run or stops
This dehumidif ie r may be full of water or water tank is not ins ta lled properly,
drain the water in water tank, or re-install water tank in correct way.
At the moment the dehumidifier may be in the
dehumidification mode”,
the ambient temperature is lower or higher (dehumidificatio n cannot be
performed when the ambient temperature is 41 or 90).
The ambient temperature for operation of the dehumidifier is 41 - 90 ,
and the relative humi dity is 30%-80%. The optimal temperature for use is
61-90;
Q: Why is hot air blown o ut from air supply outlet?
This dehumidifier extracts the air in the room, and the dehumidification unit
cools the air, the temperatur e decreases below the condensati on point, the air
condenses into water drops, which falls into water tank finally, and the
dehumidified air is heated by the temperature returning unit. This can reduce
energy consumption and also accelerate dehumidification, therefore, hot air
is blown out, and this not a fault.
EN