HiPro Troubleshooting
27
No cooling, absorber
unit warm
Refrigerator is not level Align refrigerator with
water level
Refrigerator was only switched on
recently
Check cooling again after
5 to 6 hours
Cooling unit is defective Authorized service:
Replace refrigerator
No cooling, interior
light and door opening
monitor (optional) flash
continuously
Refrigerator is not level Align refrigerator with
water level
Cooling unit blocked Contact authorized cus-
tomer service
Cooling unit not water-tight
Heating element defective
Error during self-test
Poor cooling perfor-
mance
Cooling unit not sufficiently ventilated Bring about sufficient ven-
tilation (fig. 3, page 5)
Refrigerator is exposed to direct sun-
light
Take refrigerator out of
direct sunlight
Door of refrigerator does not close
with a tight seal
Check distances (fig. 0,
page 9)
Authorized service:
Replace door seal
Refrigerator was recently filled Check cooling again after
5 to 6 hours
Frost formation in the
refrigerator compart-
ment
Door of refrigerator does not close
with a tight seal
Check distances (fig. 0,
page 9)
Authorized service:
Replace door seal
Fault Possible cause Solution
HiPro3000_4000_6000_Vision-IO-EN.book Seite 27 Dienstag, 27. November 2018 6:20 18