PGE121 Troubleshooting
33
No AC output. Generator overloaded. Reduce loads and push reset
button to reset module.
Low AC voltage. Verify the choke is on RUN
position, and check fuel in
the fuel tank and carburetor,
and check air filter.
Electrical device short circuit. Verify condition of any exten-
sion cords and all items
being powered, then push
reset button to reset module.
No DC output Low DC voltage. Verify ECO switch is on the
"0" OFF position.
DC circuit protector is OFF. Push the DC circuit protector
ON.
Fault in connected electrical
appliance.
Change or replace the appli-
ance.
Fuel leaks from drain hoses. Excessive pressure in the fuel
tank.
Open fuel tank vent to bal-
ance pressure.
The carburetor drain in bowl
is open.
Turn drain screw clockwise to
close.
The Fuel Tap is not closed
while tilting the generator.
Close the fuel tap.
Problem Cause Remedy