b. connect the gas hose to the inlet (Fig. 9.4) at the
back of the refrigerator with tools (see label at the
connection)
c. put the gas bottle assembly about 10 from the
refrigerator.
After connecting all gas connections must be
checked for leaks. For this put a soapy solution on
all gas connections, turn on the gas cylinder
manual valve and watch for bubbles.
For the detection of leaks never use an open flame.
If the gas bottle is empty withdraw it from the bottle
holder, unscrew the manual control valve /
pressure regulator-assemly from the bottle and refit
a new one.
For your safety:
Do not check for leaks with a naked flame! Do not smoke while checking for leaks!