EasyManua.ls Logo

Dometic RC2000 - Refrigerator Operation; Liquid Gas Operation

Dometic RC2000
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use a
spirit
level to check that the refrigerator is standing level in both directions. This is
important for satisfactory operation of the cooling unit
The absorption cooling unit is
cooled
by
convection
and it is therefore vitally important that the
air circulates freely over the unit and that the air vent openings of the refrigerator are
always
kept open. The more ventilation you provide, the better the performance you can expect from
the refrigerator.
NOTFS;
KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE AND OTHER LIQ
UIDS WITH FLAMMABLE VAPOURS.
DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR.
This
refrige
rator is designed for a self-contained fuel cylinder of not more than 75 cubic inches
(2
1/2
pounds nominal water capacity). The
cylinder(s)
must be made and marked in
accordance with the
specifications
for
LP-gas cylinders of the US Department of Transportation
(DOT), DOT SPEC. 39 (49CFR 178.65). In Canada, with the Ministry of Transport and
Communication.
2
Liquid
Gas Operation:
The refrigerator may only be operated using a self-contained
14
or
16,4
oz
propane HD 5 gas bottle, which is to be connected to
the refrigerator by means of-the supplied manual control valve
and the pressure regulator with hose.
The gas burner is fitted
with a jet No. 21 which is suitable for use with Propane gas at
a
supply pressure of 11 inches water gauge.
2.11
Connection of gas supply:
(FIG.2 see page 9)
a:
fix the cylinder holder
(fig. 2.1);
assembly see FIG.4, page l0.
b:
fit the manual control valve (fig. 2.2) with pressure
regulator (fig. 2.3) and hose to the
self-
contained
gas
cylinder (fig. 24) finger tight.
c:
connect the gas hose to the inlet (fig. 2.5) at the back of the refrigerator.
d:
insert the gas bottle assembly into the gas cylinder holder (fig. 2.1).
Once connected all gas connections must be checked for leaks. This is done by placing a
soapy solution on all gas connections, turn on the gas cylinder manual valve and watch for
bubbles.
For the detection of leaks never use an open flame.
If the gas
bottle
is empty remove it from the
bottle
holder, unscrew the manual control
valve/pressure regulator-assembly from the bottle and fit a new one.
3

Related product manuals