Page #26 background imageLoading...
Page #26 background image
26
The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with European Standard
EN 1949 (e.g. Ermeto).
The gas connection may only be carried out by a qualified personnel.
Following proper installation, a testing for
leakage and a flame test must be carried
out by *qualified personnel in compliance
with EN1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who
are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the lea-
kage test.
The refrigerator must be equipped with a
gas cock (C) in the supply line to allow the
supply to be disconnected. Such a cutout
device must be readily accessible to the user.
SW 14
SW 17
C
Gas pressure
Category I
3P(30)
I
3P(37)
I3P(50) I3+ I
3B/P(50)
I
3B/P(30)
mbar 30 37 50 28-37 30-37 50 30