3
5. VENTILATION HEIGHTS
Refer to FIG 1., Page 2
Installation with roof Minimum Ventilation
vent and lower side vent heights in:
REFRIGERATOR INCHES MM
RM2452, RM2453 37-3/4 960
RM2552, RM2553 44-1/2 1130
LOWER VENT CUTOUT
UPPER VENT CUTOUT
5-1/2"
21-9/16"
13-3/4"
23-3/4"
NOTE: All cutout dimensions are +/– 1/8".
6. CLEARANCES
Minimum clearances in inches to combustible materials
are:
G: Top 0"
K: Side 0"
L: Bottom 0"
M: Rear 0"
N: See NOTE
NOTE: Clearance "M" is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the
bottom of the lower vent to the roof material. For
ventilation height, refer to
Section A. Installation, Item 5.
Ventilation Heights
. See FIGS. 1 & 2.
FIG. 2
FIG. 3
Refrigerator Overall Recess Total
Model Dimensions Dimensions Ref. Vol.
Height Width Depth Height Width Depth
A B C H W D Cu. Ft.
RM2452,2453 36-7/8 24-7/8 24-7/8 36-9/16 23-11/16 24
937 632 632 928 601 608
RM2552,2553 43.0 24-7/8 24-7/8 42-5/8 23-11/16 24
1093 632 632 1082 601 608
(mm)
(In.)
(In.)
(mm)
3.7
4.7