RM(x)8xx6 Troubleshooting
41
E09 No cooling power in DC
mode
Error Check if the unit is at an
angle and adjust it if
necessary.
Reset the error manually.
Contact customer service if
this error occurs again.
W11 DC overvoltage (> 16 V). Warning Reduce DC supply voltage.
E12 Gas valve check error Error Gas operation is not
possible.
Reset the error manually.
Contact customer service if
this error occurs again.
E13 Internal communication
error
Error Gas operation not
possible.
Reset the refrigerator.
Reset the error manually.
Contact customer service if
this error occurs again.
E50 Gas lock after 3 ignition
attempts
Error Ignition not possible.
The gas cylinder is empty.
Replace the gas cylinder.
Reset the error manually.
E51 Gas lock, internal error in
the power module
Error Reset the error manually.
Contact customer service if
this error occurs again.
E52 Ground contact, gas
valve
Error Reset the error manually.
Contact customer service if
this error occurs again.
In autonomous gas
operation:
The battery charge of the
battery packs is low.
Error Insert new batteries.
Code LEDs Fault Typ e Solution