Troubleshooting RUC5(x)08X, RUC6(x)08X, RUC8(x)08X
EN
40
11.1 DC operation only
Unusual noises (e.g. loud
humming)
A component of the refrig-
erant circuit cannot move
freely (touching the wall).
Bend the component carefully away from the
obstruction.
A foreign object is located
between the cooling unit
and the wall.
Remove the foreign object.
Problem Possible cause Suggested remedy
The refrigerator does not
work. The display does not
light up.
Insulation faults, corro-
sion, breaks or loose con-
nections between the
battery and electronics
unit.
Check connections and live cables for insulation
faults, corrosion, breaks or loose connections.
Main switch defective (if
installed).
Replace the main switch.
Internal fuse has blown. Replace the internal fuse.
The fuse in the DC cable is
defective.
The fuse on the relay must be replaced.
Contact an authorized service agent.
The vehicle fuse has
blown.
Replace the vehicle fuse.
Refer to the operating manual of your vehicle.
The ignition is not
switched on.
Switch on the ignition.
The vehicle battery is
discharged.
Charge the vehicle battery.
Internal error or defective
components.
Contact an authorized service agent.
The refrigerator does not
cool.
The battery capacity is too
low.
Replace the battery.
The refrigerator is not con-
nected correctly.
Check the connections (see chapter “Connect-
ing the refrigerator to DC power supply” on
page 24).
Check the cable cross-sections and lengths
(fig. j, page 24).
Problem Possible cause Suggested remedy