domnick hunter
dh
PNEUDRI MAXI
MX102 – MX110
USER GUIDE
• GEBRUIKERSHANDLEIDING • ANWENDERHANDBUCH • GUIDE D’UTILISATION
• KÄYTTÖOPAS • BRUKSANVISNING • BRUKERVEILEDNING • BRUGERVEJLEDNING
• ΕΓΧΕΙΡΙ∆ΙΟ ΧΡΗΣΗΣ • GUÍA DEL USUARIO • GUIA DO UTILIZADOR • MANUALE UTENTE
• INSTRUKCJA UŻYTKOWNIKA • POUŽÍVATEĽSKÁ PRÍRUČKA • UŽIVATELSKÁ PŘÍRUČKA
• KASUTUSJUHEND • HASZNÁLATI ÚTMUTATÓ • LIETOTĀJA ROKASGRĀMATA
• VARTOTOJO VADOVAS • РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ • NAVODILA ZA UPORABO
• KULLANIM KILAVUZU •
GWIDA
G{ALL-UTENT

Questions and Answers

  • N
    Natalie ClarkAug 8, 2025
    What to do if my Domnick Hunter Pneudri Maxi MX105 has a high pressure drop?
    • K
      Kyle RobertsonAug 9, 2025
      To address high pressure drop in your Domnick Hunter Dryer, resulting in low pressure, first check and replace the pre/after filtration if it's nearing the end of its operational life. Also, verify the inlet conditions against the values quoted at the time of sizing to ensure the dryer isn't being overflowed or operating at a reduced system pressure. Ensure all isolation valves are fully open and inspect the system for any leaks. Confirm drain cocks and pressure relief valves are closed. Lastly, check the dryer and compressor power indicators, isolators, and fuses in case of a power supply interruption.
  • M
    Megan OrtizAug 18, 2025
    How to fix poor dewpoint in my Domnick Hunter Pneudri Maxi MX105 Dryer?
    • A
      Adam LandryAug 18, 2025
      If you notice a poor dewpoint, indicated by water in the downstream piping of your Domnick Hunter Dryer, start by checking if the dryer is operating within its sizing criteria, comparing actual inlet parameters and environmental conditions to the original sizing values. Ensure the bypass valve is fully closed and allow sufficient time for the system to dry down after a recent start. Inspect the condensate drains for any faults and make sure the drain hoses are free from kinks or obstructions. Also, ensure the drain isolation valves are fully open. If the regeneration column pressure exceeds 350mbar, replace the exhaust silencers. For timer, valve malfunctions or if the desiccant is near its end of life, contact a Domnick Hunter approved service agent.
  • L
    Leonard AndersonAug 28, 2025
    What to do if the air supply is interrupted in my Domnick Hunter Dryer?
    • J
      Jeremy HahnAug 28, 2025
      If the air supply downstream of your Domnick Hunter Dryer is interrupted, causing a rapid loss of system pressure, first check the compressor to ensure it is running. If the compressor is functioning, check the dryer fault indicators for any fault shutdown events.

Summary

Safety Information

Markings and symbols

Details markings and international symbols used on the equipment and in the user guide.

Description

Technical Specification

Provides detailed specifications including pressure, temperature, flow rates, and electrical/environmental data.

Installation & Commissioning

Electrical Installation

Covers requirements for qualified engineers, supply connection, earthing, and overcurrent protection.

Operating the equipment

Overview of Controls

Describes the three control options (MXS, MXS-DS, MXA) and their indicators/displays.

Starting the equipment

Step-by-step guide for starting the dryer, requiring trained personnel.

Stopping the equipment

Procedures for safely stopping the dryer, including depressurization and disconnection.

Troubleshooting guide

Domnick Hunter Pneudri Maxi MX105 Specifications

General IconGeneral
ModelPneudri Maxi MX105
Maximum Flow Rate105 m³/h
Operating Pressure10 bar (145 psi)
Inlet Temperature (Max)50°C (122°F)
Ambient Temperature Range1.5 to 50 °C
Power Supply230V/1ph/50Hz
CategoryRefrigerated Compressed Air Dryer
Weight128 lbs (58 kg)