Digital I/O Controller Supports outputs such as:
• Pump indicator (OPT light)
• Pump light (Red/Green light)
• Timer controller out
Also supports:
• Programmable inputs for external sources.
• Status events can be reported to remote applica-
tions, such as Doms Site Info.
Application Managers
Configuration Manager Handles various configuration methods. Primarily, Em-
bedded Configuration tool or direct POS Protocol com-
mands.
Operation Manager Manages operational changes due to, for example, the
time of day or night, rush hour traffic, or a fall-back situ-
ation.
Transaction Manager Controls storage, logging and clearance of transaction
data from clients, POS terminals or a payment server.
Price Manager Supports:
• On the fly price updates of both pumps and price
poles
• Scheduled price changes
• Price increases appear on price poles before they
are sent to the pumps
• Tagging of all transactions with price set ID.
Service Manager Includes a web menu that provides:
• Embedded trace tool
• Error history of all devices
• Real-time operational status of all devices
Embedded Payment
Server
Supports:
• Offline fuel card validation using white lists and
black lists
• Online fuel card validation using IFSF ISO 8583: Oil
protocol
• Attendant tag control and account management
Embedded Back Office
System
Supports Open and Closed reports which contain, for
example:
• Pump totalizer period changes
• Gauged wetstock changes
• Till Totals
Performance Measure-
ments
Measurements for each pump, for example peak and
average flow-rates, time to start and activity (number of
transactions).
Application Modules Features