VENTILATION
Installation Instructions
SDF100/150
Axial Wall Fans
CLEANING
Disconnect power supply before cleaning.
It is important to clean fans regularly as cleaning helps maintain performance and ensure safe, reliable operation.
The front cover can be removed from the fan and gently washed in warm water, dry throughly.
The interior of the fan can be dusted with a soft brush. Do not use water.
On humidity control models, please ensure that no water enters the sensor grille.
OPERATIONS
Timer Adjustment - Timer Models only
Isolate the power supply. The timer is factory set at midpoint. Time is set by placing the black bridge
over 2 of the pins on the right hand side of the timer board. If bridge is not fitted, timer will default to 20
minute setting. Replace front cover BEFORE switching on the power supply.
HUMIDITY ADJUSTMENT - HUMIDITY MODELS ONLY
Isolate the power supply. Remove the front cover. The humidity control adjustment position is clearly
marked. Turn clockwise for less sensitivity and anti-clockwise for greater sensitivity. Turn fully clockwise
to turn the humidity sensor off. Replace front cover BEFORE switching on the fan.
SDF 100 RANGE
230V ac - 50Hz 12W (SDF100) 35W (SDF150)
IPX4 Rating – This product is double insulated.
SDF100B Standard SDF100PB With Pull Cord
SDF100TB
With
Timer
SDF100HTB
With Humidistat
and Timer
SDF100HTBPC
With Humidistat, Timer
and Pull Cord
SDF100PIR
With Movement
Detector and Timer
SDF 150 RANGE
SDF150B Standard SDF150PB With Pull Cord
SDF150TB
With
Timer
SDF150 HTBTW
Twin Speed with
Humidistat and Pull Cord
SDF150HTB
With Humidistat
and Timer
SDF150HTBPC
With Humidistat,
and Pull Cord
SDF150PBTW
Twin Speed
and Pull Cord
30 Mins 15 Mins 5 Mins
ISSUE C
LAB038R
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Domus Ventilation
Cambria House, Caerphilly Business Park, Van Road, Caerphilly
CF83 3ED
Tel: +44 (0)3443 715523 Fax: +44 (0)3443 715524
Email: vent.info@domusventilation.co.uk
www.domusventilation.co.uk
VENTILATION