– 28 –
Description of the Unit
Functions
5
Ultrapac 2000 midi sp / 24.09.2008
US
This table shows the settings for the example USA!
pressing the button
“MODE“
short pressing of the
acknowledgement switch
pressing the but-
ton“MODE“
long pressing of the
acknowledgement switch
service mode
software rev. No.
country?
USA
country?
>USA
change displayed language
displays original value new language accepted
pressure?
102 psi
pressure?
>102 psi
change displayed value
displays original value pressure?
= 102 psi (new value accepted)
temperature?
95 °F
temperature?
>95 °F
change displayed value
displays original value temperature?
= 95 °F (new value accepted)
throttle No:
no effect next point of menu set throttle =0
shows internal data
prefilter?
no effect next point of menu prefilter?
changed!
afterfilter ?
no effect next point of menu afterfilter?
changed!
cartridge?
no effect next point of menu adsorbent?
changed!
operation:
optimised
no effect next point of menu operation:
safe
menu starts again from
the beginning