EasyManua.ls Logo

Doogee S88 - B NORMAL OPERATING CONDITION TESTS, ABNORMAL OPERATING CONDITION TESTS AND SINGLE FAULT CONDITION TESTS; B.2 Normal Operating Conditions; B.3 Simulated abnormal operating conditions

Doogee S88
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- Page 20 of 60 -
Report No. STS200421001001E
IEC/EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
2. “high sound pressure” or
equivalent wording; 3. “hearing
damage risk” or equivalent
wording; 4. “do not listen at high
volume levels for long periods” or
equivalent wording.
Equipment safeguard prevent ordinary person to
RS2 ..................................................................... :
Automatically return to RS1 level
when the power is switched off.
Means to actively inform user of increase sound
pressure .............................................................. :
Warning: hearing damage risk or
equivalent wording
Equipment safeguard prevent ordinary person to
RS2 ........................................................................ :
After 20h the acoustic output not
exceeding RS1
10.6.5 Requirements for listening devices (headphones,
earphones, etc.)
No such device N/A
10.6.5.1 Corded passive listening devices with analog
input
N/A
Input voltage with 94 dB(A) L
Aeq
acoustic
pressure output ................................................... :
10.6.5.2 Corded listening devices with digital input N/A
Maximum dB(A) .................................................. :
10.6.5.3 Cordless listening device N/A
Maximum dB(A) .................................................. :
B
NORMAL OPERATING CONDITION TESTS, ABNORMAL OPERATING
CONDITION TESTS AND SINGLE FAULT CONDITION TESTS
P
B.2 Normal Operating Conditions P
B.2.1 General requirements ......................................... : (See summary of testing &
appended test tables)
P
Audio Amplifiers and equipment with audio
amplifiers ............................................................ :
N/A
B.2.3 Supply voltage and tolerances (See appended table B.2.5) P
B.2.5 Input test ............................................................. : (See appended table B.2.5) P
B.3 Simulated abnormal operating conditions N/A
B.3.1 General requirements ......................................... : (See appended table B.3) N/A
B.3.2 Covering of ventilation openings N/A
B.3.3 D.C. mains polarity test N/A
B.3.4 Setting of voltage selector .................................. : No such voltage selector. N/A
B.3.5 Maximum load at output terminals .......................: No such terminals N/A
B.3.6 Reverse battery polarity No battery reverse polarity N/A