Report No. STS200421001001E
IEC/EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
F.3.5.3 Replacement fuse identification and rating
markings ............................................................. :
Provided the user manual.
N/A
F.3.5.4 Replacement battery identification marking ....... : Provided the user manual. P
F.3.5.5 Terminal marking location N/A
F.3.6 Equipment markings related to equipment
classification
N/A
F.3.6.1 Class I Equipment N/A
F.3.6.1.1 Protective earthing conductor terminal N/A
F.3.6.1.2 Neutral conductor terminal N/A
F.3.6.1.3 Protective bonding conductor terminals N/A
F.3.6.2 Class II equipment (IEC60417-5172) N/A
F.3.6.2.1 Class II equipment with or without functional earth N/A
F.3.6.2.2 Class II equipment with functional earth terminal
marking
N/A
F.3.7 Equipment IP rating marking .............................. : IP20, no marking is needed
F.3.8 External power supply output marking N/A
F.3.9 Durability, legibility and permanence of marking Marking is considered to be legible
and easily discernible. See also
the following details.
P
F.3.10 Test for permanence of markings The label was subjected to the
permanence of marking test. The
label was rubbed with cloth soaked
with water for 15 sec. And then
again for 15 sec. With the cloth
soaked with petroleum spirit.
After this test there was no
damage to the label. The marking
on the label did not fade. There
was no curling and lifting of the
label edge.
After each test, the marking
remained legible.
P
F.4 Instructions P
a) Equipment for use in locations where children
not likely to be present - marking
N/A
b) Instructions given for installation or initial use P
c) Equipment intended to be fastened in place N/A
d) Equipment intended for use only in restricted
access area
Not used in restricted access area. N/A