- Page 15 of 60 -
Report No. STS200421001001E
IEC/EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
6.3.1 (b) Combustible materials outside fire enclosure N/A
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard Method Method of control fire spread used P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits
N/A
6.4.3 Reduction of the likelihood of ignition under single
fault conditions in PS2 and PS3 circuits
N/A
6.4.3.1 General N/A
6.4.3.2 Supplementary Safeguards N/A
Special conditions if conductors on printed boards
are opened or peeled
N/A
6.4.3.3 Single Fault Conditions ........................................ :
N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits N/A
6.4.5 Control of fire spread in PS2 circuits
P
6.4.5.2 Supplementary safeguards .............................. : PCB: V-0;
Fire enclosure used: V-0
P
6.4.6 Control of fire spread in PS3 circuit N/A
6.4.7 Separation of combustible materials from a PIS P
6.4.7.1 General .............................................................. : Fire enclosure used: V-0 P
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a fire barrier P
6.4.8 Fire enclosures and fire barriers P
6.4.8.1 Fire enclosure and fire barrier material properties Fire enclosure provided P
6.4.8.2.1 Requirements for a fire barrier P
6.4.8.2.2 Requirements for a fire enclosure V-0 used. P
6.4.8.3 Constructional requirements for a fire enclosure
and a fire barrier
P
6.4.8.3.1 Fire enclosure and fire barrier openings No openings on the fire enclosure. N/A
6.4.8.3.2 Fire barrier dimensions N/A
6.4.8.3.3 Top Openings in Fire Enclosure: dimensions
(mm) ....................................................................... :
No opening N/A
Needle Flame test N/A
6.4.8.3.4 Bottom Openings in Fire Enclosure, condition met
a), b) and/or c) dimensions (mm) ......................... :
N/A
Flammability tests for the bottom of a fire
enclosure ............................................................... :
N/A