EasyManua.ls Logo

Doogee S88Pro - Safeguards Against Fire (Single Fault Conditions)

Doogee S88Pro
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- Page 15 of 60 -
Report No. STS200421001001E
IEC/EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
6.3.1 (b) Combustible materials outside fire enclosure N/A
6.4 Safeguards against fire under single fault conditions P
6.4.1 Safeguard Method Method of control fire spread used P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits
N/A
6.4.3 Reduction of the likelihood of ignition under single
fault conditions in PS2 and PS3 circuits
N/A
6.4.3.1 General N/A
6.4.3.2 Supplementary Safeguards N/A
Special conditions if conductors on printed boards
are opened or peeled
N/A
6.4.3.3 Single Fault Conditions ........................................ :
N/A
Special conditions for temperature limited by fuse N/A
6.4.4 Control of fire spread in PS1 circuits N/A
6.4.5 Control of fire spread in PS2 circuits
P
6.4.5.2 Supplementary safeguards .............................. : PCB: V-0;
Fire enclosure used: V-0
P
6.4.6 Control of fire spread in PS3 circuit N/A
6.4.7 Separation of combustible materials from a PIS P
6.4.7.1 General .............................................................. : Fire enclosure used: V-0 P
6.4.7.2 Separation by distance N/A
6.4.7.3 Separation by a fire barrier P
6.4.8 Fire enclosures and fire barriers P
6.4.8.1 Fire enclosure and fire barrier material properties Fire enclosure provided P
6.4.8.2.1 Requirements for a fire barrier P
6.4.8.2.2 Requirements for a fire enclosure V-0 used. P
6.4.8.3 Constructional requirements for a fire enclosure
and a fire barrier
P
6.4.8.3.1 Fire enclosure and fire barrier openings No openings on the fire enclosure. N/A
6.4.8.3.2 Fire barrier dimensions N/A
6.4.8.3.3 Top Openings in Fire Enclosure: dimensions
(mm) ....................................................................... :
No opening N/A
Needle Flame test N/A
6.4.8.3.4 Bottom Openings in Fire Enclosure, condition met
a), b) and/or c) dimensions (mm) ......................... :
N/A
Flammability tests for the bottom of a fire
enclosure ............................................................... :
N/A

Related product manuals