Report No. STS200421001001E
EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
ATTACHMENT TO TEST REPORT IEC 62368-1
DENMARK NATIONAL DIFFERENCES
Audio/video, information and communication technology equipment –
Part 1: Safety requirements
Differences according to .......... : DS/EN 62368-1:2014
Attachment Form No. ............... : DK_ND_IEC62368_1B
Attachment Originator ............. :
UL (Demko)
Master Attachment ................... : 2014-10
Copyright © 2014 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
National Differences
P
4.1.15 To the end of the subclause the following is
added:
Class I pluggable equipment type A intended for
connection to other equipment or a network shall,
if safety relies on connection to reliable earthing
or if surge suppressors are connected between
the network terminals and accessible parts, have
a marking stating that the equipment shall be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follows:
“Apparatets stikprop skal tilsluttes en stikkontakt
med jord som giver forbindelse til stikproppens
jord.”
N/A
5.2.2.2 After the 2nd paragraph add the following:
A warning (marking safeguard) for high touch
current is required if the touch current exceeds
the limits of 3,5 mA a.c. or 10 mA d.c.
N/A
5.6.1 Add to the end of the subclause:
Due to many existing installations where the
socket-outlets can be protected with fuses with
higher rating than the rating of the socket-outlets
the protection for pluggable equipment type A
shall be an integral part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
N/A