Report No. STS200421001001E
EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
G.4.2 To the end of the subclause the following is
added:
Supply cords of single phase appliances having a
rated current not exceeding 13 A shall be
provided with a plug according to DS 60884-2-
D1:2011.
CLASS I EQUIPMENT provided with socket-
outlets with earth contacts or which are intended
to be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with standard sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6-1a in DS 60884-2-D1 or EN
60309-2.
Mains socket outlets intended for providing power
to Class II apparatus with a rated current of 2,5 A
shall be in accordance DS 60884-2-D1:2011
standard sheet DKA 1-4a.
Other current rating socket outlets shall be in
compliance with Standard Sheet
DKA 1-3a or DKA 1-1c.
Mains socket-outlets with earth shall be in
compliance with DS 60884-2-D1:2011 Standard
Sheet DK 1-3a, DK 1-1c, DK1-1d, DK 1-5a or DK
1-7a
Justification:
Heavy Current Regulations, Section 6c
P