Report No. STS200421001001E
EN 62368-1
Clause Requirement + Test Result - Remark Verdict
Shenzhen NTEK Testing Technology Co., Ltd
C1
(battery)
Short
circuit
12Vdc 7hrs -- -- -- --
Unit shut down
immediately, no
damaged, no
hazard.
R1
(battery)
Short
circuit
12Vdc 7hrs -- -- -- --
EUT work as
normal, no damage,
no hazards.
Battery + to -
Short
circuit
12Vdc 10mins -- --
-- --
After SC, battery no
fire, no explosion
and no leakage, no
hazard.
Motor Locked 12Vdc 7hrs
-- -- -- --
EUT no ignition of
the wrapping
cheesecloth.
Speaker SC
12Vdc 10mins
-- -- -- --
Speaker shut down
and other function
as normal
operation. No
damaged, no
hazards.
Discharging with full charged battery
Battery
Over-
discharge
Fully
battery
7hrs -- -- -- --
Unit was normal
operation, no
damaged, no
hazard.
Battery B- to P-
(battery)
Short
circuit,
Over-
discharge
Fully
battery
7hrs -- -- -- --
Unit was normal
operation, no
damaged, no
hazard.
C1
(battery)
Short
circuit
Fully
battery
7hrs -- -- -- --
Unit shut down
immediately, no
damaged, no
hazard.
R1
(battery)
Short
circuit
Fully
battery
7hrs -- -- -- --
EUT work as
normal, no damage,
no hazards.
Battery + to -
Short
circuit
Fully
battery
10mins -- --
-- --
After SC, battery no
fire, no explosion
and no leakage, no
hazard.