INSTRUCTIONS FOR 1830-185 TCP/IP MANUAL MODE to RS-232 CONVERTER KIT
RED
BLACK
WHITE
BROWN
GREEN
SHIELD
RS-232 Cable
P/N 1818-040
(6 Ft. Cable)
RS232 wire runs
limited to 100 Ft.
Maximum. See
note above.
Network selected in Remote
Account Manager Software.
P/N 1830-181 Rev D 3-17
FUNCTION
Transmit Data
Receive Data
Request to Send
Clear to Send
Signal Ground - Shell
Not Used
BOARD
TERMINALS
DB - 9
PINS
DB - 25
PINS
1 3 2
2 2 3
3 7 4
4 8 5
5 5 7
6
Connection via INTERNET Connection via LAN
Internet
RS-232 wire terminal
on telephone entry /
access control system
circuit board
1
2
3
4
5
6
5 1
69
Red
White
Black
Brown
Shield
+
Green
3 2
8 7
Connect Converter to 1830 Series Circuit Board RS-232 Terminals
General Information
Internet
Modem
N.I.D.
1 2 3 4
Router
Modem
N.I.D.
1 2 3 4
Router
Network
Interface
Device
LAN
Network
Interface
Device
LAN
Network
Interface
Device
LAN
RS-232
A(+) B(-)
RS485
Network
Pwr
DC 5-18V
Ethernet
10M/100M
RS-232 & 485 To Ethernet
Reload Defaults
RS-232
A(+) B(-)
RS485
Network
Pwr
DC 5-18V
Ethernet
10M/100M
RS-232 & 485 To Ethernet
Reload Defaults
RS-232
A(+) B(-)
RS485
Network
Pwr
DC 5-18V
Ethernet
10M/100M
RS-232 & 485 To Ethernet
Reload Defaults
Note:
RS-232 wire runs are limited to 100
feet maximum. If greater distance
is needed, use RS232 to RS422
Extender Kit, P/N 1830-190 (4000
Feet maximum distance).
Use these instructions when using the TCP/IP adapter, part number 1830-185. This device is a manual
setup (no subscription required). For Plug and Play setup (no manual setup required) use TCP/IP adapter
part number 1830-186 (DKS Data over IP or DKS VoIP Voice + Data subscription service required).
You can use the 1830-185 Converter Kit with the following DKS Systems:
1830 Series Telephone Entry and Access Control Systems (1833, 1834, 1835, 1837, 1838).
Refer to these instruction manuals for additional information:
P/N 1835-065 Telephone Entry Systems Installation Manual
P/N 1838-065 Access Controller Installation Manual
P/N 1835-066 Remote Account Manager Software User Manual
Network selected in Remote
Account Manager Software.
Network
System IP Address
Connection Option
Model Number
Area Codes
Dial First, then
DKS Cellular
DKS Data over IP
DKS VoIP Voice + Data
IM Server Modem
Modem to Modem
Network
RS 232
Network
System IP Address
Connection Option
Model Number
Area Codes
Dial First, then
DKS Cellular
DKS Data over IP
DKS VoIP Voice + Data
IM Server Modem
Modem to Modem
Network
RS 232
Question and Answer IconNeed help?

Do you have a question about the DoorKing 1830-185 and is the answer not in the manual?

DoorKing 1830-185 Specifications

General IconGeneral
Model1830-185
CategoryMedia Converter
HousingMetal
Input Voltage12-24 VDC
Fiber Optic CompatibilityMultimode
Operating Voltage12-24 VDC

Summary

General Information

Connecting the Converter

Connection via INTERNET

Describes how to connect the 1830-185 converter to a network via the internet.

Connection via LAN

Details the process for connecting the 1830-185 converter using a local area network (LAN).

Physical Connection Diagram

Illustrates the physical wiring and terminal connections for the converter to the circuit board.

Configuration and Settings

Windows (Computer) Settings

Prepares the computer's network settings, including IP address, for converter configuration.

Connect 1830-185 for Programming

Details the physical connection steps required to program the 1830-185 converter.

Accessing the 1830-185 Menus

Guides on how to log in to the converter's web interface to access its menus and settings.

Changing 1830-185 Settings

Explains how to modify the converter's IP address, gateway, and other network parameters.