Digital Scale
INSTRUCTION MANUAL
DORAN SCALES, INC.
1315 PARAMOUNT PKWY.
BATAVIA, IL. 60510
1-800-262-6844
FAX: (630) 879-0073
http://www.doranscales.com
MANUAL REVISION: 4.0
MAN0166 12/26/2002
Model 4300
Made in USA

Table of Contents

Questions and Answers

  • T
    Thomas ChristianAug 20, 2025
    How to check if my Doran Scales 4300 weight readings are correct?
    • V
      Virginia GriffinAug 20, 2025
      If the weight readings on your Doran Scales Scales seem incorrect, verify the scale's accuracy using a test weight. If necessary, recalibrate the scale.
  • G
    Gregory SmithAug 22, 2025
    What to do if my Doran Scales Scales shows "ovr-Ld" Scale overload?
    • F
      frenchamandaAug 22, 2025
      If your Doran Scales Scales displays an "ovr-Ld" error, it indicates an overload. Verify that the platform stops are correctly set and that there are no foreign objects restraining the load cell movement. Remove all weight from the scale and recalibrate it.
  • L
    Lauren MartinezAug 25, 2025
    Why won't my Doran Scales 4300 Scales go to zero when I press the ZERO button?
    • L
      linda01Aug 25, 2025
      If your Doran Scales Scales won't zero when you press the ZERO button, ensure the scale is stable (the "MOT" enunciator is off). Also, verify that the ZERO button functions while in the setup mode. It may also be necessary to activate the latching zero feature (ZOd) or lengthen the filter time (Av A32). There may be a problem with the touch-panel or main board.
  • J
    Jamie HowardAug 26, 2025
    Why is the reading on my Doran Scales Scales bouncing?
    • C
      Christopher JordanAug 26, 2025
      If the reading on your Doran Scales Scales is bouncing or "flighty", it could be due to air currents and/or vibration around the scale. If this is the case, increase the Digital Averaging setting to stabilize the reading.
  • R
    reginaboyleAug 28, 2025
    Why does my Doran Scales 4300 keep drifting off of zero?
    • L
      Laura CaseyAug 28, 2025
      If your Doran Scales Scales drifts off zero, it may be due to air currents and/or vibration around the scale. If that's the cause, you might need to set the AZT aperture to a wider setting to compensate.
  • V
    Vanessa NewtonAug 30, 2025
    Why is my Doran Scales 4300 Scales overloading early?
    • L
      leah13Aug 30, 2025
      If your Doran Scales Scales overloads early, it's possible the scale is being shock-loaded, causing the load cell to shift. Ensure all four corner overload stops are properly set, if present. To check, remove the platter, invert it, and place it back on the spider. With half of the scale's capacity in test weights concentrated over a corner of the platform, there should be approximately 1/32" of clearance between the stop and the bottom of the spider. Check all four corners, then recalibrate the scale.
  • K
    Kristin GomezAug 31, 2025
    What does "grs-oL" Gross overload mean on my Doran Scales Scales?
    • R
      Rhonda ParkerSep 1, 2025
      If your Doran Scales Scales displays a "grs-oL" error, remove all weight from the scale. If the problem persists, inspect the load cell connections to the scale electronics. Recalibration will not resolve this issue, as it indicates a hardware error. The load cell may be damaged. Check all overload stops, ensure no foreign objects are inside the platform, and inspect the load cell cables for cuts or damage.
  • A
    Aaron MurraySep 2, 2025
    Why won't my Doran Scales 4300 weight reading repeat or return to zero?
    • R
      rebeccacervantesSep 2, 2025
      If the weight reading on your Doran Scales Scales doesn't repeat or the scale doesn't return to zero after removing weight, make sure nothing is caught in the platform under or around the load cell or spider that could interfere with its movement.
  • C
    Christopher GriffithSep 4, 2025
    Why won't my Doran Scales 4300 Scales indicate full capacity or overload?
    • J
      jenniferbaldwinSep 4, 2025
      If your Doran Scales Scales won't indicate full capacity or go into overload, ensure nothing is caught in the scale under or around the load cell or spider that could interfere with their movement. If clear, check the overload stops.
  • S
    Sonya MaxwellSep 6, 2025
    What does "SPAn Er" Span Error mean on my Doran Scales Scales?
    • T
      Tracy SwansonSep 6, 2025
      If your Doran Scales Scales shows "SPAn Er" Span Error, check the capacity of the load cell. If the scale is set to a low percentage of the load cell capacity, there may not be enough signal from the load cell to calibrate the meter. Set the meter's capacity to match the load cell capacity and recalibrate. Also, set the meter resolution to the designated weighing resolution.

Summary

Scale Operation and Buttons

Front Panel Button Functions

Details on the function and operation of the five pressure-sensitive switches on the scale's front panel.

Using the Zero Button

Explanation of the ZERO button's function for zeroing the scale and its zero band limitations.

Using the Units Button

Describes how to use the UNITS button to change measurement units and its configuration parameters.

Checkweighing Operations

Basic Over;Under;Accept Operation

Step-by-step guide for performing basic checkweighing using OVER, UNDER, and ACCEPT lights.

Digital Entry of Over;Under Limits

Procedure for entering checkweighing limits digitally using the scale's buttons.

Push-button Entry of Over;Under Limits

Method for entering checkweighing limits via button presses, an optional configuration.

Scale Calibration

Performing Zero Calibration

Step-by-step guide for performing zero calibration of the scale.

Span Calibration Methods

Details on performing span calibration using full, half, quarter, or 1/10th load.

Analog Setup

Analog Setup and Raw Counts Verification

Procedure for verifying load cell output and span using raw counts.

Detailed Parameter Setup

Accessing Configuration Menu

Instructions for accessing and exiting the scale's configuration setup menu.

Accessing Calibration Menu

Instructions for accessing and exiting the scale's calibration setup menu.

Calibration Menu Options

Zero Calibration Mode

Procedure for performing the zero calibration of the scale.

Span Calibration Modes

Procedure for performing span calibration at various capacity levels.

Manual Calibration Weight Entry

Procedure for manually dialing in a specific weight value for calibration.

Printer Data Output Setup

Printer Data Output Modes

Determining when serial data will be sent from the scale.

Output Formats Setup

Serial Data Output Formats

Defining the appearance and content of the serial data sent by the scale.

Baud Rate Setup

Serial Data Handshaking

Push-button Function Setup

Password Protection Setup

Checkweighing Operation

Checkweighing Operation Modes

Activating specific checkweighing modes, including Legal for Trade.

Legal For Trade Setup

Legal For Trade Setup Modes

Activating Legal for Trade mode and selecting compliance standards.

Password Entry Setup

Scale Output Commands (TXD)

Troubleshooting Guide

General Troubleshooting Steps

Common problems and their corresponding solutions for the Model 4300 scale.

Resetting Scale Parameters to Default

Procedure to restore scale setup parameters to factory defaults, requiring recalibration.

Doran Scales 4300 Specifications

General IconGeneral
BrandDoran Scales
Model4300
CategoryScales
LanguageEnglish