EasyManua.ls Logo

Doran 2200CW Series - User Manual

Doran 2200CW Series
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
2200CW Series
Digital Checkweighing Indicator
Technical Manual
MAN347 Rev E Doran Scales, Inc. www.doranscales.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Doran 2200CW Series and is the answer not in the manual?

Summary

Scale Setup and Unpacking

Unpacking Your Scale

Instructions for safely removing the scale from its packaging and handling precautions.

Scale Controls and Operation

Scale Annunciators

Explanation of the indicator lights (NET, battery, zero) on the scale's front panel.

Powering On

Instructions on how to turn on the scale using the power cord or battery.

Basic Weighing Operation

Steps for performing a basic weighing operation on the scale.

ZERO Function

Function of the ZERO button for zeroing the scale and returning to gross mode.

TARE Function

Process of taring the scale to net weight using the TARE button or keyboard entry.

GROSS;NET Selection

How to switch between gross and net weighing modes on the scale.

UNITS Selection

Function of the UNITS button to change the displayed unit of measure.

PRINT Function

How to transmit data from the scale to a printer or external device.

Checkweigh Limit Entry (OVER;UNDER)

Using OVER/UNDER buttons to set checkweigh limits.

Password Protected Values

Battery Operation

Power Off Modes

Methods for manually or automatically powering off the scale.

Low Battery Indication

How the scale indicates a low battery status.

Recharging Battery

Steps and information on how to recharge the scale's battery.

Checkweighing Operations

Three Band Checkweighing Operation

Steps for performing three-band checkweighing.

Setting Checkweigh Limits

How to enter and view checkweigh limits using digital or reference entry.

Five Band Checkweighing Operation

Steps for performing five-band checkweighing.

Setting High and Low Limits

How to enter and view high/low limits using digital or reference entry.

Zero Band Checkweighing Operation

Steps for performing zero-band checkweighing.

Setting Zero Band Limits

Using a reference weight to set limits for zero-band checkweighing.

Product ID Management

Recalling Product IDs

How to load a stored product ID via number or barcode scan.

Creating and Displaying Product IDs

Steps for creating a new product ID and viewing the current one.

Delete Product ID from Memory

User ID Management

User ID Login and Logout

Processes for logging into and out of the scale using a user ID.

Barcode Entry of User IDs

Using a barcode scanner to enter user ID values.

Time and Date Settings

Accumulator and Counter Functions

Operation and Data Handling

Covers accumulator/counter operation, display, clearing, and data output.

Installation Guide: Rear Panel Access

Load Cell Connection

Power and Communication Connections

Power Connection and Fuse

Information on connecting the power supply and replacing the fuse.

RS232 and Remote Switch Connection

Wiring instructions for RS232 ports and remote switch connections.

Output Connections

Calibration Guide

Entering and Exiting Setup Mode

Methods to access and exit the calibration and setup menus.

Setting Scale Capacity

Procedure to set the maximum capacity of the scale.

Scale Count By and Calibration

Setting Scale Count By (Resolution)

How to set the scale's resolution or count by value.

Calibration Process

Steps for performing the scale calibration process.

Calibration Error Codes

List and explanation of common calibration error codes.

Scale Calibration Error Troubleshooting

Scale Parameter Setup

Entering and Exiting Setup Mode

Methods to access and exit the calibration and setup menus.

Navigating Parameter Menu

How to move through the scale's parameter menu structure.

Parameter Groups Overview

Legal for Trade Restrictions

Audit Counters and Software Info

Capacity and Calibration Settings

Capacity Adjustment (CAP AU)

Details on adjusting the scale's capacity.

Count By Setup Menu (Cntby)

Configuration of the scale's count by or resolution.

Calibration Mode Settings (CAL)

Procedures for zero calibration and entering calibration weight.

Display Filter Setting (809)

Settings for the display filter to adjust response speed.

Automatic Zero Tracking and Motion Settings

Automatic Zero Tracking Range (826*)

Configuration of the automatic zero tracking range.

Motion Aperture and Delay

Settings for motion aperture and delay for motion indication.

Start Up Zero and Tare Input

Configuration of start-up zero behavior and tare input methods.

Zero;Print on Demand and Operating Modes

Zero on Demand (2 od)

Configuration for zero on demand feature.

Print on Demand (Pod)

Configuration for print on demand feature.

Operating Mode Selection (oP)

Selection of operating modes (standard, NTEP, CWM).

Exit Calibration and Setup (donE)

Options for exiting calibration and setup modes.

General Settings

Unit Enable Disable (CSL)

Enables or disables specific unit selections for the scale.

Start Up Units Select Mode (Un5)

Configures the startup units displayed on power up.

Push Button Enable and Disable (P.6.)

Timer, Threshold, and Default Settings

Automatic Off Timer (५४५)

Settings for the automatic off timer.

Threshold Level Entry (EXS)

Configuration for threshold level entry for automatic printing.

Restore Factory Defaults (DEFE)

Options to restore factory default parameter values.

Counts, Brightness, and Battery

Information on counts, LED brightness, and battery operation settings.

Password Protection (PASS)

Serial Port 1 Configuration

Data Output Mode Port 1 (d.o.1)

Configures data output mode for Serial Port 1.

Data Output Format Port 1 (For. 1)

Selects data output format for Serial Port 1.

Serial Port 2 Configuration

Data Output Mode Port 2 (d.o. 2)

Configures data output mode for Serial Port 2.

Data Output Format Port 2 (For. 2)

Selects data output format for Serial Port 2.

Wired Ethernet Configuration

Data Output Mode Ethernet (d.o. E)

Configures data output mode for Wired Ethernet.

Data Output Format Ethernet (For. E)

Selects data output format for Wired Ethernet.

Network IP and Port Settings

IP Address Assignment (IPxxxx)

Configuration for static or DHCP IP address assignment.

Static IP Address Assignment (IP Adr)

Static IP address assignment settings for the scale.

Subnet Mask (Subnet)

Setting the subnet mask for network configuration.

IP Gateway (9 AŁE)

Setting the IP gateway for network connectivity.

TCP Port Number (Port)

Configuration of the TCP port number for the scale.

Ethernet MAC Address (nn8 c)

Displays the unique Ethernet MAC address.

Analog Output Adjustments

Adjustments for 4mA and 20mA analog output points.

Wireless Ethernet Configuration

Data Output Mode Wifi (d.o. Uu)

Configures data output mode for Wireless Ethernet.

Data Output Format Wifi (For. UU)

Selects data output format for Wireless Ethernet.

Network Status and Settings

IP Address and Subnet Settings

Static IP address and subnet mask configuration.

IP Gateway and TCP Port

Configuration for IP gateway and TCP port number.

Idle Timeout and MAC Address

Settings for idle timeout and display of Ethernet MAC address.

Wifi Connection Status (C5)

Displays the status of the wireless network connection.

Bluetooth Configuration

Data Output Mode Bluetooth (d.০. ১৮)

Configures data output mode for Bluetooth.

Data Output Format Bluetooth (For. b)

Selects data output format for Bluetooth.

USB Configuration

Data Output Mode USB (d.o. 56)

Configures data output mode for USB.

USB Data Output Format

Checkweigh and Output Operation Modes

Checkweigh Operation Modes

Lists various checkweigh operation modes and their descriptions.

Checkweighing Status Conditions

Defines status conditions for three, five, and zero-band checkweighing.

Checkweigh Limit Entry

Output Configuration Settings

Exit Menu Options

Data Communications

Data Communication Modes

Overview of the four data transmission modes available.

Auto Print Modes

Details on Auto Print 1, 2, and 3 data transmission modes.

Data String Formatting

Standard Data Output Formats

Standard and Dual Unit Formats

Details on standard and dual unit lb/kg output formats.

Label Printer and Emulation Formats

Details on label printer output and model 8000 emulation formats.

Custom Data String Formats

Custom Data String 1 & 2

Formats for custom data strings 1 and 2.

Custom Data String 3 & 4

Formats for custom data strings 3 and 4.

Custom Data String Configuration Details

Remote Indicator Commands

Bluetooth Option Overview

Bluetooth Specifications

Bluetooth Pairing Instructions

Internal Relay Option

Internal Relay Setup and Specifications

Information on internal relay setup and technical specifications.

Internal Relay Output Cable Color Code

Step-up Relay Circuit

4-20 mA Analog Output Option

Wired Ethernet Option

Wireless 802.11 b;g Ethernet Option

Bluetooth Option Overview

Bluetooth Specifications

Bluetooth Pairing Instructions

Troubleshooting Common Problems

Scale Problems and Solutions

Common issues with the scale and steps to diagnose and resolve them.

Scale Messages Explained

Explains common messages displayed on the scale and their meanings.

Error Messages and Troubleshooting

Default to Factory Settings

Doran 2200CW Series Specifications

General IconGeneral
TouchscreenYes
Operating System CompatibilityWindows, Linux
Serial Ports1 x RS-232/422/485
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 60°C
Display TypeTFT LCD
InterfaceEthernet, USB
Humidity10% to 90% non-condensing
MountingPanel